Need Help? or Have something for sale? USE THIS FORM:
|
|
|
|
|
|
|
|
Chillers
|
 |
|
|
|
207381
165 Ton @ -32 degrees F, Dunham Bush horizontal screw refrigeration package. Water cooled design. R22 Refrigerant. Compressor Model 2515/5.40, Horizontal Rotary Screw, rated 3550 RPM, direct coupled to a Siemens 600 HP, 3/60/460 volt motor. Evaprator is a 2 pas, 24" diamter x 176" long, (288) 3/4" x 0.049 x 176" long trufin tube carbon steel tubes; Condensor is a 2 pass, 18" diameter, x 153" long, (228) 3/4" x 0.028" x 153" long tubes, trufin copper tubes. All skid mounted with lubeoil system, and digital control panel. With Westinghouse starter WYE-Delta Closed Transition, NEMA-1 encloser floor mount. Unit dimensions are 212" L x 8"W x 116" H, 24,500 lbs.
Read More...
|
| |
|
|
|
|
|
|
|
|
Used BoilersUsed Hot Oil or Thermal Fluid Boilers Hot Oil or Thermal Fluid Boilers often are used to heat equipment in process plant applications.
High temperatures can be reached using thermal fluid boilers vs steam. The hot oil or thermal fluid is heated by passing the thermal fluid around electric heating elements. On lager units, the thermal fluid is passed though tubes or coils that are heated on the outside by a flame created by burning fuel. The different fuels that are burned include Oil (typically # 2 or # 6 grade), Natural Gas, and combinations of Oil and Gas. The typical configurations of hot oil heater/hot oil boilers are horizontal, vertical, or packaged design.
Used Steam Boilers Boilers are used to create steam or hot water for process plant applications. Certain plants use steam or hot water (vs. a thermal fluid) to heat their reactors and heat exchangers for cooking their products. Boilers are also crucial in Power Generation plants or Co-Generation Plants where you use steam to generate electricity.
The steam or hot water is heated by passing water either through tubes or around tubes that are heated by a flame. The flame is created by burning some type of fuel. The different fuels that are burned include Coal, Pulverized Coal, Oil (typically # 2 or # 6 grade), Natural Gas or combinations of Oil and Gas. There are also steam boilers that heat the water by using the waste heat generated from another process in the plant to heat the water to create steam. In the trash industry there are "Trash to Steam" boilers that burn trash to generate the steam. The typical configurations of steam boilers are water tube and fire tube. This indicates whether the heat source surrounds the tubes and the water is in the tubes (water tube), or the heat source goes through the tubes and the water surrounds the tubes (fire tube). Many smaller boilers are the fire tube type, while many very large boilers are the water tube type.
|
|
Enter a product number or part of its description below and click SEARCH
Finally, you may filter the results based on capacity below
| 43 Items Returned | Go To Page: | 1 | 2 | 3 |
|
| | | Stock Number | Product | Sub Group | Capacity | Description |
|
|
| 22049 | BOILER | HOT OIL | 6 | 6.55MM Hy-Way hot oil heater. Mdl 67CFH, SN 2656. Hev-E-Oil burner, mfd by Industrial Engineers, Mdl AM5CM, SN G8872. Fires #6 fuel. |
|
|
| 22130 | BOILER | HOT OIL | 1 | 1.2MM BTU Dowtherm vaporizer. Mfd by Foster Wheeler, SN 23-584, NB #5945. Rated 150 psi, 435 sq ft. Chamber is refractory lined. W/Mdl SBI-2010 Hauck blower w/10 HP, 3/60/230/460 volt, 3500 rpm motor. |
|
|
| 33205 | BOILER | HOT OIL | 4 | 3.75MM BTU/hr (2MM min) Union Iron Works hot oil boiler. SN 22181, NB #3261. Int rated 150 psi @ 750 deg F. North American natural gas premix burner. Gas pilot ignition. Gas pressure being boosted by North American turbo blower, Mdl 306G-C1-3/4, rated 300 cfm. Direct driven by 3/4 HP, 3/60/208/220/440 volt, 3450 rpm. Secondary air supplied by 3/4 HP, 3/60/220 volt, 3515 rpm motor. Flame safety by Flame King. |
|
|
| 33343 | BOILER | HOT OIL | 6 | 5.75MM BTU/hr @ 150 psi, 750 deg F, Process Combustion hot oil heater. Mdl EPE-0676-33, SN 1466-045. Horiz design. Oil fired. |
|
|
| 43274 | BOILER | HOT OIL | 10 | 10.0MM BTU input portable Parker thermal liquid heater system. Serial # 40225 and 40226. Unit has (2) trailer mtd Mdl HT-5000 boilers. Each rated ASME 125 psi, 5.0MM BTU output. Propane fired. Furnished fully assembled in special insulated cabinet w/burner and operating controls mtd and electrically wired in compliance w/normally accepted FM standards. Both unit mtd in tandum on 40' trailer for portable use. |
|
|
| 43354 | BOILER | HOT OIL | 2 | 1.75MM BTU/hr Struthers Wells direct fired Dowtherm heater w/economizer. SN 58F-6261, NB #47. Int rated 200 psi @ 750 deg F. 5'6" OD x 13' str side. Refractory lined, 4'6" ID. 228 sq ft surface area, 18 pass, with 4 1/2" dia vert tubes. Has John Zinc type DBA-14 gas or oil fired burner mtd thru btm. Mtd on (4) legs. 12" dia x 15' long stack. W/Dean Bros 304SS circulating pump, 300 gpm @ 105'TDH (no motor). Economizer is mfd by Chanute, 403 sq ft. Rated 200 psig @ 750 deg F. (18) 4 1/2" dia x 4'10" long CS tubes, NB rated. |
|
|
| 76234 | BOILER | HOT OIL | 14 | 84,500 BTU/hr, 26 KW, Youngtown Miller hot oil system. SN HT1068, Type HT26-1S. Rated 35 gpm, rated temp 500 deg F to 700 deg F. Unit has (3) electric heating elements, Class 1, Group D. W/expansion tank mtd over cabinet. Cabinet size 32" wide x 36" deep x 70" high. Complete unit w/circulating pumps. |
|
|
| 76671 | BOILER | HOT OIL | 0 | 500,000 BTU/hr @ 750 deg F, 146 KW, hot oil heater. Mfd by Konus-Kessel, Mdl KVO-16/25, SN 435109, Order #118752000. 163 psi @ 750 deg F. 259 gal capacity. Maxon Mdl 408M burner package, rated 600,000 BTU/hr. Maxon combustion air fan with 3/4 HP motor. Main circulation pump, Dickow NML cast iron, 56 gpm, 45 psi @ 730 deg F, w/10 HP, 3500 rpm motor. Recirculation pump, Dickow NKL, cast iron, 20 gpm, 60 psi @ 630 deg F w/5 HP, 3500 rpm motor. System requires 116 gal CS expansion tank, rated 150 psi @ 650 deg F. |
|
|
| 78338 | BOILER | HOT OIL | | Sterlco 9 KW/zone water dual zone temp control unit. Mdl M8422-GX, SN 44663, blt 1983. Rated at up to 300 deg F. Has 3 HP TEFC motor/pump. Electricals: 3/60/460 volt. |
|
|
| 78514 | BOILER | HOT OIL | 0 | Approx 100,000 BTU/hr (30 KW) CS hot oil heater. Mfd by Patterson Ind, SN 65-1507, NB #1262. 18" dia x 30" str side horiz CS tank, dish head, w/(2) 15 KW electric heating elements mtd in 6" flange nozzle in each head. With 3/4" high pressure level indicator. Tank rated for 100 psi @ 700 deg F. Shell 5/16" thick, heads 1/4". Openings: top 1-1 1/2", 1-1", 3-3/4"; 1" btm outlet. |
|
|
| 83317 | BOILER | HOT OIL | 9 | 9.0MM BTU/hr, Loveco CS direct fired gas oil heater. SN C-79-131, NB #2, Mdl NDEO686-18EK, blt 1980. Max allowable working pressure 150 psi @ 700 deg F. Heating surface 3180 sq ft. Heating coil openings: 2-4" inlets, 2-4" outlets. W/Bloom gas burner, SN PE-0679-15, Type 1026-100. Includes gas train panel and controls. Oil circulating pump not included. Skid mtd. |
|
|
| 83879 | BOILER | HOT OIL | 1 | 1,024,000 BTU Gessner exp-proof hot oil heater. Mfd by Youngstown-Miller, SN HT-1381, Mdl HT-3001X. 300 KW, 3/60/480 volt, 392 amps. Unit has (3) 100 KW heating columns. Total oil capacity 100 gal. 1,024,000 BTU Gessner exp-proof hot oil heater. Mfd by Youngstown-Miller, SN HT-1381, Mdl HT-3001X. 300 KW, 3/60/480 volt, 392 amps. Unit has (3) 100 KW heating columns. Total oil capacity 100 gal. |
|
|
| 87197 | BOILER | HOT OIL | | 300 KW Chromolox hot oil system. (6) heaters, 8" dia x 5' long. W/Dean Bros 20 HP circulation pump. |
|
|
| 106465 | BOILER | HOT OIL | | 30 KW Chromolox hot oil heater. Catalogue #PFV65030, SN A25182, P/N #141120853007. 3/60/240 volt. Has (2) 15 KW heaters. Complete w/120 volt gauges and controls and circulation pump. |
|
|
| 110627 | BOILER | HOT OIL | 0 | Fulton hot oil heater, 110 kw, 375,000 BTU/hr, Serial# 37582, NB# 37585. Model# FT0375N. 480 volt, with Worthington 15 hp 3" x 2" CS circulation pump. |
|
|
| 111813 | BOILER | HOT OIL | 4 | 4.0MM BTU/HR, CS, THERMINOL 66 HEATING SYSTEM, Manufacturered by Smith-Moon Steel; SN# 72-03-31289; NB# 593; 'S' stamped; stamped for 700 deg F. 710 sq. ft. heating surface, including radiant coil = 310 sq.ft. and conventional coil = 400 sq.ft. Rated for 150 psi. Carbon steel tubes. Burner by North American Manufacturing Co. Model # 214 8B. Diameter of Furnace 6', elevation to bottom of furnace from grade 78". Height of furnace with out economizer 15' Economizer dimensions;5' high x 5' long x 3.5" wide. Caged ladder to platform with railings (2.6' x 4') for economizer inspection. 16" diameter x 17' high stack with drip cap. |
|
|
| 203173 | BOILER | HOT OIL | 1 | 850,000 BTU/Hr First Thermal Fluid Heater, Model: 50-1.5-1-HHC-PG-G-UL-N4-T/C Heater, Manufacturer: First Thermal Systems, Louisville, KY, Order Number: 71620, ASME Number: 95121, Plant Number: E-12-000. Horizontal design. 89 square foot heating surface area, Certified by Heatec, Inc. Serial # 95121, NB # 272, rated for 300 psi at 800 degrees F. With newer V Power Flame Burner, Model # JR 30A-10, Serial # 038786326, Rated for Natural Gas, min: 600 MBH, 1075 Max. BTH. Operated on 115 volts. Skid mount design, horizontal heater, with controls mounted on unit. |
|
|
| 204507 | BOILER | HOT OIL | 1 | 1400 KW Oil heater, Manufactured by Heiza Mattil GmbH, Serial number 6870, rated 100 CuM/Hr flow, -1 to 10 bar @ 350 degrees C, 1454 liter. Overall dimensions 2100mm W x 7800 mm Overall height. With Weisshaupt Type DK2-2, combined oil/gas burners, 2.6 KW, 3/50. Includes some spares. |
|
|
| 207995 | BOILER | HOT OIL | 0 | Hot Oil System |
|
|
| 213039 | BOILER | HOT OIL | 1 | 48 KW Mokon Hot Oil Heater, Model HC 4B24-T4, Serial Number 16194, 2 zone, each zone is 24 KW, 2 HP, 3/60/460V. Skid mounted. |
| 43 Items Returned | Go To Page: | 1 | 2 | 3 |
|
|
|
|
|
IPP Sales Contacts
|
 |
|
Keith West Global Sales KeithW@ippe.com +1 609 838 5931 | Amanda Vagell Global Sales AmandaV@ippe.com +1 609 838 5929 | Patti Buchman Global Sales PattiB@ippe.com +1 609 838 5928 | Ray Wagner Global Sales RayW@ippe.com +1 609 838 6043 | Regina Zarmer Europe Sales & Acquisitions ReginaZ@ippe.com +49-306-594-2445 Office +49-172-313-8439 Mobile +49-30-6594-2448 Fax | Jo Petrie, Sales Engineer UK, Scandinavia, Spain, & So.Africa jop@ippe.com +44 (0)1642 367 910 Office +44 (0)1642 367 913 Direct +44 (0)7770 748884 Mobile +44 (0)1642 367 920 Fax | Bohumil Cuta, E. Europe Sales & Acquisitions BohumilC@ippe.com +42-054-821-6680 Office +42-060-273-7517 Mobile +420-5-481-22240 Fax | Elisa Lucumi Central & So. America Sales ElisaL@ippe.com +1 609 838 5927
|
|
|
|
|
|
|
|