 |
|
Need Help? or Have something for sale? USE THIS FORM:
|
|
|
|
|
|
|
|
Featured Equipment
|
 |
|
|
|
70291
****UNUSED 26 sq ft (2.5 sq meter) titanium automatic chamber filter press for filtering suspension having 10-500 Kg/cu meter (.65-31.5 lbs/cu ft) solids content. Capable of performing in sequence the following operations: filtration, 1st cake pressing, cake washing, 2nd cake pressing, cake air drying and cake discharge. Filter press plates closing and clamping by (2) hydraulic cylinders acting in parallel on the (2) sides of a central hydraulic operated mech fixing wedge. Filtering area 2.5 sq meter (27 sq ft). Chamber volume: cake capacity total 0.11 cu meter (3.9 cu ft). (6) filtering plates. Max thickness of cake 35mm (1 3/8"). Max operating pressure 16 Kg/sq cm (228 psi). Operating temps: max -80 deg C (176 deg F); min -5 deg C (41 deg C). Hydraulic powerpak pressures: 150 Kg/sq cm (2130 psi) - plates clamping; 20 Kg/sq cm (284 psi) - valves operating. Total installed electric power 28.3 KW. Hydraulic powerpak; low pressure pump 1.1 KW; high pressure pump 3 KW. Filter belt drive 2.2 KW, pressing water pump 22 KW. Filter belt tensioning by hydraulic motor. Overall dimensions: length 2820mm (9'3"); width 2200mm (7'3"); height 2860mm (9'4-1/2"). Matl of construction: frame, plates table and upper counter plate - cast iron and weld CS structure; filter plates and integrated manifolds - titanium; valves (fabricated) - titanium; diaphragms - rubber, suitable for alkali and acid of up to 30% concentration @ 100 deg C; belt rollers - rubber lined CS cylinders; belt wash chamber - titanium; leakage vat - titanium.
Read More...
|
| |
|
|
|
|
|
|
|
|
Used Boilers
Used Hot Oil or Thermal Fluid Boilers
Hot Oil or Thermal Fluid Boilers often are used to heat equipment in process plant applications. High temperatures can be reached using thermal fluid boilers vs steam.
The hot oil or thermal fluid is heated by passing the thermal fluid around electric heating elements. On lager units, the thermal fluid is passed though tubes or coils that are heated on the outside by a flame created by burning fuel.
The different fuels that are burned include Oil (typically # 2 or # 6 grade), Natural Gas, and combinations of Oil and Gas.
The typical configurations of hot oil heater/hot oil boilers are horizontal, vertical, or packaged design.
Used Steam Boilers
IPP offer many different types of Steam Boilers including Fire Tube, Economizers, Hot Water Heaters, Waste Heat, and Water Tube Boilers.
Boilers are used to create steam or hot water for process plant applications. Certain plants use steam or hot water (vs. a thermal fluid) to heat their reactors and heat exchangers for cooking their products. Boilers are also crucial in Power Generation plants or Co-Generation Plants where you use steam turbines to generate electricity.
The steam or hot water is heated by passing water either through tubes (Water Tube) or around tubes that are heated by a flame (Fire Tube and Scotch Marine). The flame is created by burning some type of fuel. The different fuels that are burned include Coal, Pulverized Coal, Oil (typically # 2 or # 6 grade), Natural Gas, Waste Heat, or combinations of Oil and Gas.
There are also steam boilers that heat the water by using the waste heat generated from another process in the plant to heat the water to create steam. In the trash industry there are "Trash to Steam" boilers that burn trash to generate the steam.
The typical configurations of steam boilers are water tube and fire tube. This indicates whether the heat source surrounds the tubes and the water is in the tubes (water tube), or the heat source goes through the tubes and the water surrounds the tubes (fire tube). Many smaller boilers are the fire tube type, while many very large boilers are the water tube type.
IPP has a large inventory of Used, Unused, and Reconditioned oil heaters and boilers as well as boiler accessories. Manufacturers include: A O Smith, Adamson Global Technology, Babcock & Omnical, Babcock & Wilcox, Burnham, CEMLINE, Challenger, CLEAVER BROOKS, E. Keeler, Electro, ELECTRO STEAM, First Thermal, Foster Wheeler, Fulton, GEKA, H K D, HEATEFLEX, Holman, Hurst, Kam, KAM THERMAL, Keeler, Kewanee, Loveco, MIURA, Nebraska, Newpoint, Parker, Patterson Kelley, Pfaudler, RAYPACK, Sellers, SELLERS BOILER, Stokes, Superior, Sussan, Syltherm, Thies/Funke, Triple S, Triple S Dynamics, Vapor, Vapor Power International, Viessman, VIESSMAN ATOLA, VIESSMAN HORICELL .
|
|
IPPE Used Process Equipment Search Enter a product number or part of its description below and click SEARCH
Finally, you may filter the results based on capacity below
| 52 Items Returned | Go To Page: | 1 | 2 | 3 |
|
| | | Stock Number | Product | Sub Group | Capacity | Description |
|
|
| 13918 | BOILER | STEAM | | 687,000 BTU input @ 125 psi HW, Cleaver Brooks fire tube steam boiler. Mdl CB900112, SN L46804. Natural gas or oil fired. 32.3 gph. |
|
|
| 17432 | BOILER | STEAM | 18200 | ****18,200 lbs/hr @ 120 psi, high voltage electrode steam boiler. Mfd by Hydro Steam Ind, Model BBJ-2C, SN 61781, NB #11769, blt 1985. Rated 12.2 KV. Complete unit w/5000 KVA isolation transformer; 26,000 lb/hr deaerator; (2) 20 HP feedwater pumps; water softener. |
|
|
| 70330 | BOILER | STEAM | | 360 gpm, 150 psi water pressure, Parker hot water boiler. Mdl T-4600, SN 22441, NB #22441. 573 sq ft heating surface. Natural gas fired. 4,600,000 BTU/hr input; 3,680,000 BTU/hr output, 80% efficiency. Capacity 360 gpm, 20 deg F temp rise. 4" inlet, 5" outlet. |
|
|
| 87320 | BOILER | STEAM | 2226 | 2,226 lbs./hr. at 150 psi, Bryan Flextube water tube boiler. Mdl CL270-S-150-FD0, Bryan #890988, SN 67881, NB #27374, blt 1990. 322 sq ft heating surface. Oil fired. Burner mfd by Gordon-Platt, Type R10.9-0-10. Firing rate max 19.3 gph, min 12.0 gph. 2.7 million BTU/hr. Input max 1350 MBH, min 2700 MBH. 3/60/460 volt motor. Control 1/60/120. Cabinet enclosed, skid mtd. W/complete controls. |
|
|
| 97172 | BOILER | STEAM | 50000 | 50,000 lbs/hr @ 260 psi, Cleaver Brooks water tube boiler. Mdl D-76, SN 67017, NB #44150, Unit #WL-2821. Design pressure 260 psi. Burner supply pressure 100 psi. Combination gas and oil fired. #6 fuel oil. 428 gph; propane gas 140 scfh. Heating surface: boiler 3595 sq ft; waterwall 634 sq ft. Burner mfd by Cleaver Brooks, Type WT600X-CN3, SN WL-2821. Firing rate input 72.125MM BTU/hr. 3/60/460 volt, UL label. |
|
|
| 99101 | BOILER | STEAM | 25000 | 25,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34309. Twin burners mfd by Hanworthy Ltd, Mdl AW1-35. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15.6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 7.5 HP forced induction blowers. Has control panel. |
|
|
| 99102 | BOILER | STEAM | 25000 | 25,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34310. 220 psi max. Twin burners mfd by Hanworthy Ltd, Mdl AW1-35. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15'6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 7.5 HP forced induction blowers. Has control panel. |
|
|
| 99103 | BOILER | STEAM | 25000 | 25,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34311. Twin burners mfd by Hanworthy Ld, Mdl AW0-30. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15'6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 10 HP forced induction blowers. Has control panel. |
|
|
| 99104 | BOILER | STEAM | 28000 | 28,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN 6606. 220 psi max. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184) 3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower. |
|
|
| 99105 | BOILER | STEAM | 28000 | 28,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN 6607. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184) 3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower. |
|
|
| 99106 | BOILER | STEAM | 28000 | 28,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN CM7580. 220 psi max. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184)_3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower. |
|
|
| 100180 | BOILER | STEAM | 5021 | 5,021 lbs/hr @ 150 psi steam and water, 150 HP, Kewanee fire tube boiler. Type #H35-150-05, SN P7047. 750 sq ft heating surface. 6' x 12' firing chamber area. Max working pressure: steam 150 lb. Oil fired. Firing range: oil 14-56 gpm; max firing rate: 6278 MBH. Safety valve capacity 6000 lb/hr. Cust order #432245, UL listed #P338953. Burner mfd by Ray Burner Co, SN 305563, Type PAECP-144, Size 150. 3/60/208 volt. 2.10 to 6.28 million BTU. UL listed #P74362. Unit shares (3) water feed tanks/(3) pumps w/stk #100181. Tanks: 300 gal CS (mtd above pumps); 70 gal and 9 gal (cut loose). Pumps: (2) working @ 22 gpm, (1) switchable backup for #1 and #2 boilers. |
|
|
| 105872 | BOILER | STEAM | 13800 | 13,800 lbs/hr @ 200 psi, 400 HP, Cleaver Brooks fire tube boiler. Mdl CB600-400, SN L-66404. Combination gas and oil fired. Input 16,738,000 BTU/hr. UL label. 16'11" long x 9'8" wide x 10'8" high. Skid mtd. |
|
|
| 108051 | BOILER | STEAM | 20000 | Approx 20,000 lbs/hr @ 150 psi; 25,103,000 BTU/hr, 600 HP, Cleaver Brooks water tube boiler. Model #CB786-600, Serial #L-49067. Natural gas fired. Burner manufactured by Cleaver Brook. Includes pumps. Overall length: 24' long x 15' high. |
|
|
| 202353 | BOILER | STEAM | 21569 | 21569 Lb/Hr @ 150 PSI, 500 HP, fire tube packaged boiler. Manufactured by Cleaver Brooks model CB600-500, serial number L-57788. Dual fuel, natural gas/ oil fired. Blower driven by 15HP 3/60/460 V motor. Oil heater rated 7.5 kW. Input 20,922,000, Boiler size 8' wide x 20' long x 10' high. |
|
|
| 203564 | BOILER | STEAM | 10350 | 300 HP, 10350 lbs/hr, Cleaver Brooks Fire Tube Boiler, 150 psig, CB293-300, serial number 52932, rated 12553000 btu/hr natural gas, 89.5 gph oil. Packaged design. |
|
|
| 203565 | BOILER | STEAM | 20000 | Approx 20,000 lbs/hr, 600HP, 20,700 lbs/hr Cleaver Brooks Fire Tube Boiler, 150 psi, CB 293-600. Serial number 52931. Rated 25,106,000 BTU natural gas, 179.5 gph oil. |
|
|
| 205165 | BOILER | STEAM | 13800 | 13,800 lbs./hr., at 150 psi, 400 HP, Superior Combustion, water tube, package boiler. (4 Pass) Model # N4, Serial # 6032-6389. 20270 sq.ft. heating surface area, 13,390,000 btu/hr. Combination gas and oil fired. Burner manufactured by Superior, Air atomizing, Type “N”. With Fireye flame safeguard system.
Dimensions overall lenght;18'3.25" Overall height;10' 2.75", overall width; 9' 3". |
|
|
| 205167 | BOILER | STEAM | 10000 | 300 HP Continental Packaged Firetube Boiler, rated 150 PSI, natural gas fired, serial # E12B350C-4210-5G436, HS 1500. Thickness - SH 7/16, HD 9/16. |
|
|
| 205659 | BOILER | STEAM | 30000 | 30,000 Lbs/Hr, 250 psi, Babcock and Wilcox water tube boiler. 3291 sq ft, 406 degrees F steam, National Board number 22915, built 1969. |
| 52 Items Returned | Go To Page: | 1 | 2 | 3 |
|
|
|
|
|
IPP Sales Contacts
|
 |
|
|
Keith West Global Sales Email Keith Direct: 1-609-838-5931 Office: 1-609-586-8004 |
Amanda Vagell Global Sales Email Amanda Direct: 1-609-838-5929 Office: 1-609-586-8004 |
Patti Buchman Global Sales Email Patti Direct: 1-609-838-5928 Office: 1-609-586-8004 |
Ray Wagner Global Sales Email Ray Direct: 1-609-838-6043 Office: 1-609-586-8004 |
|
Central Europe Sales & Acquisitions
Regina Zarmer Email Regina Office: 49-306-594-2445 Mobile: 49-172-313-8439 Fax: 49-30-6594-2448 |
UK, Scandinavia, Spain & South Africa Sales & Acquisitions
Office: 44 (0)1642-367-910 Fax: 44 (0)1642-367-920
Jo Petrie Email Jo Direct: 44 (0)1642-367-913 Mobile: 44 (0)7770-748-884
Nicola Douglas Email Nicola Mobile: 44 7940 981 681 |
Eastern Europe Sales & Acquisitions
Bohumil Cuta Email Bohumil Office: 42-054-821-6680 Mobile: 42-060-273-7517 Fax: 42-054-812-2240 |
Central & South America Sales
Elisa Lucumi Email Elisa Direct: 1-609-838-5927 Office: 1-609-586-8004
|
|
|
|
|
|
|
|