****UNUSED 26 sq ft (2.5 sq meter) titanium automatic chamber filter press for filtering suspension having 10-500 Kg/cu meter (.65-31.5 lbs/cu ft) solids content. Capable of performing in sequence the following operations: filtration, 1st cake pressing, cake washing, 2nd cake pressing, cake air drying and cake discharge. Filter press plates closing and clamping by (2) hydraulic cylinders acting in parallel on the (2) sides of a central hydraulic operated mech fixing wedge. Filtering area 2.5 sq meter (27 sq ft). Chamber volume: cake capacity total 0.11 cu meter (3.9 cu ft). (6) filtering plates. Max thickness of cake 35mm (1 3/8"). Max operating pressure 16 Kg/sq cm (228 psi). Operating temps: max -80 deg C (176 deg F); min -5 deg C (41 deg C). Hydraulic powerpak pressures: 150 Kg/sq cm (2130 psi) - plates clamping; 20 Kg/sq cm (284 psi) - valves operating. Total installed electric power 28.3 KW. Hydraulic powerpak; low pressure pump 1.1 KW; high pressure pump 3 KW. Filter belt drive 2.2 KW, pressing water pump 22 KW. Filter belt tensioning by hydraulic motor. Overall dimensions: length 2820mm (9'3"); width 2200mm (7'3"); height 2860mm (9'4-1/2"). Matl of construction: frame, plates table and upper counter plate - cast iron and weld CS structure; filter plates and integrated manifolds - titanium; valves (fabricated) - titanium; diaphragms - rubber, suitable for alkali and acid of up to 30% concentration @ 100 deg C; belt rollers - rubber lined CS cylinders; belt wash chamber - titanium; leakage vat - titanium.
Read More...
 
  

 

Used Boilers

Used Hot Oil or Thermal Fluid Boilers

Used Hot Oil BoilersHot Oil or Thermal Fluid Boilers often are used to heat equipment in process plant applications.  High temperatures can be reached using thermal fluid boilers vs steam.

The hot oil or thermal fluid is heated by passing the thermal fluid around electric heating elements. On lager units, the thermal fluid is passed though tubes or coils that are heated on the outside by a flame created by burning fuel.

The different fuels that are burned include Oil (typically # 2 or # 6 grade), Natural Gas, and combinations of Oil and Gas.

The typical configurations of hot oil heater/hot oil boilers are horizontal, vertical, or packaged design.

Used Steam Boilers

IPP offer many different types of Steam Boilers including Fire Tube, Economizers, Hot Water Heaters, Waste Heat, and Water Tube Boilers.

Used Steam BoilersBoilers are used to create steam or hot water for process plant applications. Certain plants use steam or hot water (vs. a thermal fluid) to heat their reactors and heat exchangers for cooking their products. Boilers are also crucial in Power Generation plants or Co-Generation Plants where you use steam turbines to generate electricity.

The steam or hot water is heated by passing water either through tubes (Water Tube) or around tubes that are heated by a flame (Fire Tube and Scotch Marine). The flame is created by burning some type of fuel. The different fuels that are burned include Coal, Pulverized Coal, Oil (typically # 2 or # 6 grade), Natural Gas, Waste Heat, or combinations of Oil and Gas.

There are also steam boilers that heat the water by using the waste heat generated from another process in the plant to heat the water to create steam. In the trash industry there are "Trash to Steam" boilers that burn trash to generate the steam.

The typical configurations of steam boilers are water tube and fire tube. This indicates whether the heat source surrounds the tubes and the water is in the tubes (water tube), or the heat source goes through the tubes and the water surrounds the tubes (fire tube). Many smaller boilers are the fire tube type, while many very large boilers are the water tube type.

IPP has a large inventory of Used, Unused, and Reconditioned oil heaters and boilers as well as boiler accessories. Manufacturers include:  A O Smith, Adamson Global Technology, Babcock & Omnical, Babcock & Wilcox, Burnham, CEMLINE, Challenger, CLEAVER BROOKS, E. Keeler, Electro, ELECTRO STEAM, First Thermal, Foster Wheeler, Fulton, GEKA, H K D, HEATEFLEX, Holman, Hurst, Kam, KAM THERMAL, Keeler, Kewanee, Loveco, MIURA, Nebraska, Newpoint, Parker, Patterson Kelley, Pfaudler, RAYPACK, Sellers, SELLERS BOILER, Stokes, Superior, Sussan, Syltherm, Thies/Funke, Triple S, Triple S Dynamics, Vapor, Vapor Power International, Viessman, VIESSMAN ATOLA, VIESSMAN HORICELL .

Equipment Search

IPPE Used Process Equipment Search


Enter a product number or part of its description below and click SEARCH
  Search View Quote Contents


Finally, you may filter the results based on capacity below

    Narrow Results by Capacity

Add Checked to Quote
 Add to Quote Before Changing Page

52 Items ReturnedGo To Page: 123
  Stock NumberProductSub GroupCapacityDescription
Details
IPP Equipment Search Image 13918BOILERSTEAM 687,000 BTU input @ 125 psi HW, Cleaver Brooks fire tube steam boiler. Mdl CB900112, SN L46804. Natural gas or oil fired. 32.3 gph.
Details
IPP Equipment Search Image 17432BOILERSTEAM 18200****18,200 lbs/hr @ 120 psi, high voltage electrode steam boiler. Mfd by Hydro Steam Ind, Model BBJ-2C, SN 61781, NB #11769, blt 1985. Rated 12.2 KV. Complete unit w/5000 KVA isolation transformer; 26,000 lb/hr deaerator; (2) 20 HP feedwater pumps; water softener.
Details
IPP Equipment Search Image 70330BOILERSTEAM 360 gpm, 150 psi water pressure, Parker hot water boiler. Mdl T-4600, SN 22441, NB #22441. 573 sq ft heating surface. Natural gas fired. 4,600,000 BTU/hr input; 3,680,000 BTU/hr output, 80% efficiency. Capacity 360 gpm, 20 deg F temp rise. 4" inlet, 5" outlet.
Details
IPP Equipment Search Image 87320BOILERSTEAM22262,226 lbs./hr. at 150 psi, Bryan Flextube water tube boiler. Mdl CL270-S-150-FD0, Bryan #890988, SN 67881, NB #27374, blt 1990. 322 sq ft heating surface. Oil fired. Burner mfd by Gordon-Platt, Type R10.9-0-10. Firing rate max 19.3 gph, min 12.0 gph. 2.7 million BTU/hr. Input max 1350 MBH, min 2700 MBH. 3/60/460 volt motor. Control 1/60/120. Cabinet enclosed, skid mtd. W/complete controls.
Details
IPP Equipment Search Image 97172BOILERSTEAM 5000050,000 lbs/hr @ 260 psi, Cleaver Brooks water tube boiler. Mdl D-76, SN 67017, NB #44150, Unit #WL-2821. Design pressure 260 psi. Burner supply pressure 100 psi. Combination gas and oil fired. #6 fuel oil. 428 gph; propane gas 140 scfh. Heating surface: boiler 3595 sq ft; waterwall 634 sq ft. Burner mfd by Cleaver Brooks, Type WT600X-CN3, SN WL-2821. Firing rate input 72.125MM BTU/hr. 3/60/460 volt, UL label.
Details
IPP Equipment Search Image 99101BOILERSTEAM 2500025,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34309. Twin burners mfd by Hanworthy Ltd, Mdl AW1-35. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15.6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 7.5 HP forced induction blowers. Has control panel.
Details
IPP Equipment Search Image 99102BOILERSTEAM 2500025,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34310. 220 psi max. Twin burners mfd by Hanworthy Ltd, Mdl AW1-35. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15'6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 7.5 HP forced induction blowers. Has control panel.
Details
IPP Equipment Search Image 99103BOILERSTEAM 2500025,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34311. Twin burners mfd by Hanworthy Ld, Mdl AW0-30. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15'6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 10 HP forced induction blowers. Has control panel.
Details
IPP Equipment Search Image 99104BOILERSTEAM 2800028,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN 6606. 220 psi max. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184) 3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower.
Details
IPP Equipment Search Image 99105BOILERSTEAM 2800028,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN 6607. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184) 3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower.
Details
IPP Equipment Search Image 99106BOILERSTEAM 2800028,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN CM7580. 220 psi max. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184)_3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower.
Details
IPP Equipment Search Image 100180BOILERSTEAM50215,021 lbs/hr @ 150 psi steam and water, 150 HP, Kewanee fire tube boiler. Type #H35-150-05, SN P7047. 750 sq ft heating surface. 6' x 12' firing chamber area. Max working pressure: steam 150 lb. Oil fired. Firing range: oil 14-56 gpm; max firing rate: 6278 MBH. Safety valve capacity 6000 lb/hr. Cust order #432245, UL listed #P338953. Burner mfd by Ray Burner Co, SN 305563, Type PAECP-144, Size 150. 3/60/208 volt. 2.10 to 6.28 million BTU. UL listed #P74362. Unit shares (3) water feed tanks/(3) pumps w/stk #100181. Tanks: 300 gal CS (mtd above pumps); 70 gal and 9 gal (cut loose). Pumps: (2) working @ 22 gpm, (1) switchable backup for #1 and #2 boilers.
Details
IPP Equipment Search Image 105872BOILERSTEAM1380013,800 lbs/hr @ 200 psi, 400 HP, Cleaver Brooks fire tube boiler. Mdl CB600-400, SN L-66404. Combination gas and oil fired. Input 16,738,000 BTU/hr. UL label. 16'11" long x 9'8" wide x 10'8" high. Skid mtd.
Details
IPP Equipment Search Image 108051BOILERSTEAM 20000Approx 20,000 lbs/hr @ 150 psi; 25,103,000 BTU/hr, 600 HP, Cleaver Brooks water tube boiler. Model #CB786-600, Serial #L-49067. Natural gas fired. Burner manufactured by Cleaver Brook. Includes pumps. Overall length: 24' long x 15' high.
Details
IPP Equipment Search Image 202353BOILERSTEAM2156921569 Lb/Hr @ 150 PSI, 500 HP, fire tube packaged boiler. Manufactured by Cleaver Brooks model CB600-500, serial number L-57788. Dual fuel, natural gas/ oil fired. Blower driven by 15HP 3/60/460 V motor. Oil heater rated 7.5 kW. Input 20,922,000, Boiler size 8' wide x 20' long x 10' high.
Details
IPP Equipment Search Image 203564BOILERSTEAM10350300 HP, 10350 lbs/hr, Cleaver Brooks Fire Tube Boiler, 150 psig, CB293-300, serial number 52932, rated 12553000 btu/hr natural gas, 89.5 gph oil. Packaged design.
Details
IPP Equipment Search Image 203565BOILERSTEAM20000Approx 20,000 lbs/hr, 600HP, 20,700 lbs/hr Cleaver Brooks Fire Tube Boiler, 150 psi, CB 293-600. Serial number 52931. Rated 25,106,000 BTU natural gas, 179.5 gph oil.
Details
IPP Equipment Search Image 205165BOILERSTEAM1380013,800 lbs./hr., at 150 psi, 400 HP, Superior Combustion, water tube, package boiler. (4 Pass) Model # N4, Serial # 6032-6389. 20270 sq.ft. heating surface area, 13,390,000 btu/hr. Combination gas and oil fired. Burner manufactured by Superior, Air atomizing, Type “N”. With Fireye flame safeguard system. Dimensions overall lenght;18'3.25" Overall height;10' 2.75", overall width; 9' 3".
Details
IPP Equipment Search Image 205167BOILERSTEAM10000300 HP Continental Packaged Firetube Boiler, rated 150 PSI, natural gas fired, serial # E12B350C-4210-5G436, HS 1500. Thickness - SH 7/16, HD 9/16.
Details
IPP Equipment Search Image 205659BOILERSTEAM3000030,000 Lbs/Hr, 250 psi, Babcock and Wilcox water tube boiler. 3291 sq ft, 406 degrees F steam, National Board number 22915, built 1969.
52 Items ReturnedGo To Page: 123

Add Checked to Quote
 Add to Quote Before Changing Page
  

IPP Sales Contacts Minimize

Keith West
Global Sales
Email Keith
Direct: 1-609-838-5931
Office: 1-609-586-8004

Amanda Vagell
Global Sales
Email Amanda
Direct: 1-609-838-5929
Office: 1-609-586-8004

Patti Buchman
Global Sales
Email Patti
Direct: 1-609-838-5928
Office: 1-609-586-8004

Ray Wagner
Global Sales
Email Ray
Direct: 1-609-838-6043
Office: 1-609-586-8004

Central Europe
Sales & Acquisitions

Regina Zarmer
Email Regina
Office: 49-306-594-2445
Mobile: 49-172-313-8439
Fax:   49-30-6594-2448

UK, Scandinavia, Spain & South Africa Sales & Acquisitions

Office: 44 (0)1642-367-910
Fax:    44 (0)1642-367-920

Jo Petrie
Email Jo
Direct: 44 (0)1642-367-913 Mobile: 44 (0)7770-748-884

Nicola Douglas
Email Nicola
Mobile: 44 7940 981 681

Eastern Europe
Sales & Acquisitions

Bohumil Cuta
Email Bohumil
Office: 42-054-821-6680
Mobile: 42-060-273-7517
Fax:    42-054-812-2240

Central & South America Sales

Elisa Lucumi
Email Elisa

Direct: 1-609-838-5927
Office: 1-609-586-8004

     

New/Unused & Exotic Alloy Heat Exchangers
Shell and Tube, Plate, Spiral

image of new unused alfa laval plate heat exchanger
image of titanium plate heat exchanger

Gas Fired CHP Cogen 10MW Power Plant

Burns Biogas, Landfill, Methane & Natural Gas

image of landfill gas chp cogen power plant

NEW/UNUSED HASTELLOY® C-276 Reactors.
Most Built 2011.

image of unused hastelloy c276 reactor

New Unused Sulzer Boiler Feed Water Pumps

image of unused surplus Sulzer MBN pump #214894
 

image of Unused Sulzer MBN pump #214895

Home | About Us | News | Contact Us | Equipment Search | Plant Search | Industrial Real Estate | Sell to IPP | Mailing List | IPP's eBay Store | PDF Downloads | Events
  Copyright 2002-2012 International Process Plants   Terms Of Use  Privacy Statement   
The European Petrochemical Association International Fertilizer Industry Association Institute of Scrap Recycling Industries, Inc. National Demolition Association National Demolition Association Turnaround Management Association Association Memberships
Bookmark and Share

Follow Us On Twitter View Our Channel on YouTube