RegisterLogin

Sell Your Equipment

Have surplus or idled equipment assets? Turn them into cash you can use to help your business by selling to IPP.

Learn About IPP's Purchase Capabilities

See Specific Plants & Equipment We are Looking to Buy

Need Help? or
Have something for sale? USE THIS FORM:
  

Featured Equipment
Equipment Rotator image
Equipment Rotator image 1 of 10 Equipment Rotator imageEquipment Rotator imageEquipment Rotator image
211011
Model D36, 316SS Podbielniak centrifuge, Manufactured by APV, Model D36, Serial number P53C01406, Job # 106-101. Bowl is 38" OD x 39" Long. Hinged 304SS cover, CS coated bottom housing. Unit has a 2"
Read More...
 
  

 

Used Chillers, Used Refrigeration Compressors & Used Cooling Towers

Used ChillersInternational Process Plants has many used chillers for sale and other used processing equipment for use in industrial refrigeration.

Much like a Boiler is used to heat a process, a Chiller and other Refrigeration equipment is typically used to cool a process.

Chillers work by compressing a refrigeration gas (R132A, Freon, R22) into a liquid, and using a special refrigeration valve, releasing the compressed liquid back into a gas.

The conversion of the liquid back into a gas removes heat and creates cold. It is the same principal as when you use a can of compressed air to clean your computer keyboard. The longer you release the compressed air, the colder the can gets.

You use the cold that is created by using a heat exchanger for liquid cooling or air exchanger if you are cooling air.

Chillers are grouped by the type of compressor:

  • Centrifugal
  • Screw Type
  • Reciprocating

Chillers are further grouped by the type of cooling used to dispense the heat generated:

  • air cooled (radiators)
  • water cooled (condensers)

Chillers are typically a packaged design with the compressor, condenser, evaporator, pumps, valves and controls all skid mounted.

Chillers are often distinguished by the Tons of Refrigeration they produce and at what temperature. A rule of thumb to use when looking for the capacity of a chiller is 1 ton of refrigeration @ 40 degrees F for each horsepower the compressor uses. The lower the discharge temperature, the more horsepower is required.

Cooling towers are designed to take water that is heated during the refrigeration process and cool it quickly by passing it through a cooling tower where large fans cool the water.

Used, Unused, and re-conditioned Chillers instock. maufacturers include: Advantage, AEC, BAC, Berg, Bry-Air, Budzar, Carrier, Cincinnati, Conair, Cooling Technologies, DUNHAM BUSCH, Dunham/Bush, Fasti, FES, Frick, FTS SYSTEMS, GES, Jensen, Kinectic Dispersion, McQuay Snyder, McSaw, Neslab, R, Sterlco, Teco, Thermalcare/Mayer, Trane, Trane Co, Transtore, York .

Equipment Search

IPPE Used Process Equipment Search


Enter a product number or part of its description below and click SEARCH
  Search View Quote Contents


Finally, you may filter the results based on capacity below

    Narrow Results by Capacity

Add Checked to Quote
 Add to Quote Before Changing Page

35 Items ReturnedGo To Page: 12
  Stock NumberProductSub GroupCapacityDescription
Details
IPP Equipment Search Image 86034CHILLERWATER COOLED 6565 ton @ 0 deg F, packaged water cooled chiller. Mfd by Freezing Equip Sales Inc. (1) rotary screw compressor, 75 HP direct coupled. Mfd by FES, Mdl 65-HE, SN 1212363. Package includes condenser, shell and tube evaporator, circulating pump. Skid mtd.
Details
IPP Equipment Search Image 86035CHILLERWATER COOLED 65UNUSED 65 ton @ 0 deg F, packaged water cooled chiller. Mfd by Freezing Equip Sales Inc. (1) rotary screw compressor. Mfd by FES, Mdl 65-HE, SN 1212077. Includes condenser, shell and tube evaporator, circulating pump. No motor. Skid mtd.
Details
IPP Equipment Search Image 101415CHILLERWATER COOLED 7575 ton @ 40 deg F, York water cooled chiller. Mdl LCH75W-46XB, SN YBRM037238. R-22 refrigerant. (1) York reciprocating, hermetically sealed compressor. High side 300, low side 150. 3/60/460 volt. Includes condenser, shell and tube evaporator, controls. Controls 1/60/115 volt. Skid mtd.
Details
IPP Equipment Search Image 201633CHILLERWATER COOLED1010 ton @ 40 degrees F. Edwards chiller. Model CE2AHP, serial number 017288R.
Details
IPP Equipment Search Image 201677CHILLERWATER COOLED2020 Ton @ 32 deg F York Packaged Chiller. Package # YCR377VU46, SN# SECM342220. 3/60, 460 volt. Rated 300 PSI high side, 150 PSI low side. Has (2) Model J564F-045-595 hermetically sealed compressors. Includes shell & tube condenser & evaporator. LCD readout. Mounted on skid.
Details
IPP Equipment Search Image 205038CHILLERWATER COOLED600600 ton @ 40 degrees F, York CodePack water cooled packaged chiller, R22 refrigerant. York Model # YKP2N2G4-CTBS. With York compressor Model YDHA41SD, Serial number GFDM310817. Condenser NB # 68826, Serial # 059S 363716. Rated for shell side 265 psi at 225 degrees F, tube side 150 psi at 175 degrees F. Built in 1995. Water box connections in/out are 10", NB # 68824, serial # 0595-365576, built in 1995, shell rated for 265 psi at 120 degrees F, tubes rated for 150 psi at 125 degrees F. Compressor driver is manufactured by Toshiba, High Efficiency 3 phase Induction motor. Type T1KK. Rated for 501 HP at 3600 rpm. Serial # 95404880. Motor control is by York Solid State motor starter, Model # SSS26LK-46A, serial # 00374H0595. INS Codepack Digital control center, Panel # 371-01200-004, Diagram # 035-09324-000, Serial # 00829H0295. Skid weight 28,000 lbs. and OAD are 6' wide x 13' long x 6' high. Motor only weighs 2,480 lbs. Unit has been decommissioned and prepared for storage by York.
Details
IPP Equipment Search Image 205039CHILLERWATER COOLED600600 ton @ 40 degrees F, York CodePack water cooled packaged chiller, R22 refrigerant. York Model # YKP2N264-CTBS. With York compressor Model YDHA41SD, Serial number GFM310817. Condenser NB # 68523, Serial # 059S 072269. Rated for shell side 265 psi at 225 degrees F, tube side 150 psi at 175 degrees F. Built in 1995. Water box connections in/out are 10", NB # 68830, serial # 0595-372324, built in 1995, shell rated for 265 psi at 120 degrees F, tubes rated for 150 psi at 125 degrees F. Compressor driver is manufactured by Toshiba, High Efficiency 3 phase Induction motor. Type T1KK. Rated for 501 HP at 3600 rpm. Motor control is by York Solid State motor starter, Model # SSS26LK-46A, serial # 01976H0595. INS Codepack Digital control center, Panel # 371-01200-004, Diagram # 035-09324-000, Serial # 01542H0595. Skid weight 28,000 lbs. and OAD are 6' wide x 13' long x 6' high. Unit has been decommissioned and prepared for storage by York.
Details
IPP Equipment Search Image 205378CHILLERWATER COOLED0Trane Chiller, 2E5R41L, Serial number N2E5OU8811.
Details
IPP Equipment Search Image 205655CHILLERWATER COOLED350350 ton @ 38 to 28 degrees F, York Codepak packaged chiller. R11, 900 gpm, Model YTJ1K3E2-CTES. Compressor Model YDTH-120, serial number MRP497131, driven by a 500 HP, 3/60/4160V motor. Digital controls.
Details
IPP Equipment Search Image 207354CHILLERWATER COOLED300300 ton(down to)- 600 ton(up to) at 40 degrees water cooled packaged chiller. manufactured by Carrier, Model # 19XL5353493CQ. Serial # 3396J52309. Requires 1850 lbs. feild charge of R-134A refrigerant. Centifugal compressor Serial # 52309, Model # OLYB493CQ. Test pressure 375 psi, operating pressure 300 psi. With hermeticly sealed drive motor. Waterbox & evaporater nozzles are 8". Electronic controls. Waterbox (Condenser), serial # 523095, NB # 202731, Model # 09XB54010201. Rated for 300 psi at 150 degrees F on the shell. Evaperator, Serial # 523094, NB # 202730, Model # 10XB54009501. Rated for 300 psi at 150 degrees F. Overall dimensions are 15' long x 6'6" wide x 9' high.
Details
IPP Equipment Search Image 207356CHILLERWATER COOLED310340 ton @ 40 degrees F, York Codepak packaged chiller. Model # YKLCLB64-CMCS. With York ISN Codepak Digital Control Center. Compressor Model # YDHA-41DD (speed code-NK), Serial # SNDM-845270. Compressor driven by a Toshiba High Efficiency Induction Motor, 310 HP, Enclosure DD, 575 volts, rpm 3600, continuous duty. With a York Solid state motor starter model # SSS14LK-58 rated for 575v, 3ph, 60 hz. Refrigerant 134 A, Liquid DWP 180, 2 pass, 1125 lbs. and York "K" Oil at 20 gallons. Package Includes Cooler rated for 816 gpm, at 25.1ft., Condenser rated for 1020 gpm at 26.4 ft. Chiller tube sheet by York Serial # M833890-95, NB # 19378. Shell rated for 180 psi at 225 degrees F, Tubes rated for 150 psi at 175 degrees F. Condensor Serial # M833880, NB # 19377, rated for shell side 180 pis at 225 degrees F, tube side 150 psi at 175 degrees F. Overall shipping dimensions 16'4" long x 6' 6" wide x 8'6" high. Feild electric supply needed, 575 v, 3 ph, 60 hz.
Details
IPP Equipment Search Image 207357CHILLERWATER COOLED310340 ton @ 40 degrees F, York Codepak packaged chiller. Model # YKLCLB64-CMCS. With York ISN Codepak Digital Control Center. Compressor Model # YDHA-41DD (speed code-NK), Serial # SNDM-845290. Compressor driven by a Toshiba High Efficiency Induction Motor, 310 HP, Enclosure DD, 575 volts, rpm 3600, continuous duty. With a York Solid state motor starter model # SSS14LK-58 rated for 575v, 3ph, 60 hz. Refrigerant 134 A, Liquid DWP 180, 2 pass, 1125 lbs. and York "K" Oil at 20 gallons. Package Includes Cooler rated for 816 gpm, at 25.1ft., Condenser rated for 1020 gpm at 26.4 ft. Chiller tube sheet by York Serial # M833890-95, NB # 19378. Shell rated for 180 psi at 225 degrees F, Tubes rated for 150 psi at 175 degrees F. Condensor Serial # M833910-95, NB # 19380, rated for shell side 180 pis at 225 degrees F, tube side 150 psi at 175 degrees F. Overall shipping dimensions 16'4" long x 6' 6" wide x 8'6" high. Feild electric supply needed, 575 v, 3 ph, 60 hz.
Details
IPP Equipment Search Image 210989CHILLERWATER COOLED1515 Ton, Flakice Corporation package chiller Model #FPCW40. 180,000 BTU, designed for conditions of service to chill 45 gpm of 50% Ethylene Glycol solution from 15 degrees F to 5 degrees F. Skid mounted design includes a Carrier Model 5H60 reciprocating compressor, (6 cylinder and 35.9 BHP), 50 hp at 1750 rpm TEFC hi efficiency drive motor, a Bell and Gosset Model 57685 Condenser, chiller, oil cooler, oil separator and accumulator. Charged with R-22 refrigerant. Overall dimensions; 113” long x 49” wide x 62” high. Requires 51 gpm cooling water flow. (75 gpm at pulldown)
Details
IPP Equipment Search Image 211404CHILLERWATER COOLED4040 HP, FES refrigeration compressor skid, Model 25E, 3555 RPM, driven by a 40 HP 3/60/460 Volts. With MICR Master Controls.
Details
IPP Equipment Search Image 212706CHILLERWATER COOLED750750 Ton @ 40-60 Degree F Chilled water, Trane Absorption Chiller, Model ABSC 750, Serial Number L93C03791, single stage. Operates on Nominal 12 psig steam or Nominal 270 degrees F hot water. These chillers use 18 pph of low pressure steam per ton of cooling.(13,500 pph of 9-12 psi steam) Utility rate is controlled by the leaving chilled water set point. Chilled water flow rate is up to 1766 gpm, and can be set from 40-60 degrees F. These absorption chillers use water as the refrigerant and Lithium Bromide as the absorbent. Both of the items are non- toxic. Main components of the chiller are the generating section, the condenser, the evaporator, and the absorber. Additional components include the heat exchanger, solutions pumps, control valves and electronic microprocessor controls. These models use the Trane single pump system with 3 impellers, 15HP 3/60/460 volt, FLA 12A, max fuse size 45 a, purge pump 1/4 HP, 1/60/115 volt.
Details
IPP Equipment Search Image 212707CHILLERWATER COOLED750750 Ton @ 40-60 Degree F Chilled water, Trane Absorption Chiller, Model ABSC 750, Serial Number L93F06351, single stage. Operates on Nominal 12 psig steam or Nominal 270 degrees F hot water. These chillers use 18 pph of low pressure steam per ton of cooling.(13,500 pph of 9-12 psi steam) Utility rate is controlled by the leaving chilled water set point. Chilled water flow rate is up to 1766 gpm, and can be set from 40-60 degrees F. These absorption chillers use water as the refrigerant and Lithium Bromide as the absorbent. Both of the items are non- toxic. Main components of the chiller are the generating section, the condenser, the evaporator, and the absorber. Additional components include the heat exchanger, solutions pumps, control valves and electronic microprocessor controls. These models use the Trane single pump system with 3 impellers, 15HP 3/60/460 volt, FLA 12A, max fuse size 45 a, purge pump 1/4 HP, 1/60/115 volt.
Details
IPP Equipment Search Image 212708CHILLERWATER COOLED750750 Ton @ 40-60 Degree F Chilled water, Trane Absorption Chiller, Model ABSC 750, Serial Number L93F06349, single stage. Operates on Nominal 12 psig steam or Nominal 270 degrees F hot water. These chillers use 18 pph of low pressure steam per ton of cooling.(13,500 pph of 9-12 psi steam) Utility rate is controlled by the leaving chilled water set point. Chilled water flow rate is up to 1766 gpm, and can be set from 40-60 degrees F. These absorption chillers use water as the refrigerant and Lithium Bromide as the absorbent. Both of the items are non- toxic. Main components of the chiller are the generating section, the condenser, the evaporator, and the absorber. Additional components include the heat exchanger, solutions pumps, control valves and electronic microprocessor controls. These models use the Trane single pump system with 3 impellers, 15HP 3/60/460 volt, FLA 12A, max fuse size 45 a, purge pump 1/4 HP, 1/60/115 volt.
Details
IPP Equipment Search Image 212709CHILLERWATER COOLED750750 Ton @ 40-60 Degree F Chilled water, Trane Absorption Chiller, Model ABSC 750, Serial Number L93F06348, single stage. Operates on Nominal 12 psig steam or Nominal 270 degrees F hot water. These chillers use 18 pph of low pressure steam per ton of cooling.(13,500 pph of 9-12 psi steam) Utility rate is controlled by the leaving chilled water set point. Chilled water flow rate is up to 1766 gpm, and can be set from 40-60 degrees F. These absorption chillers use water as the refrigerant and Lithium Bromide as the absorbent. Both of the items are non- toxic. Main components of the chiller are the generating section, the condenser, the evaporator, and the absorber. Additional components include the heat exchanger, solutions pumps, control valves and electronic microprocessor controls. These models use the Trane single pump system with 3 impellers, 15HP 3/60/460 volt, FLA 12A, max fuse size 45 a, purge pump 1/4 HP, 1/60/115 volt.
Details
IPP Equipment Search Image 212710CHILLERWATER COOLED750750 Ton @ 40-60 Degree F Chilled water, Trane Absorption Chiller, Model ABSC 750, Serial Number L93C03745, single stage. Operates on Nominal 12 psig steam or Nominal 270 degrees F hot water. These chillers use 18 pph of low pressure steam per ton of cooling.(13,500 pph of 9-12 psi steam) Utility rate is controlled by the leaving chilled water set point. Chilled water flow rate is up to 1766 gpm, and can be set from 40-60 degrees F. These absorption chillers use water as the refrigerant and Lithium Bromide as the absorbent. Both of the items are non- toxic. Main components of the chiller are the generating section, the condenser, the evaporator, and the absorber. Additional components include the heat exchanger, solutions pumps, control valves and electronic microprocessor controls. These models use the Trane single pump system with 3 impellers, 15HP 3/60/460 volt, FLA 12A, max fuse size 45 a, purge pump 1/4 HP, 1/60/115 volt.
Details
IPP Equipment Search Image 212711CHILLERWATER COOLED750750 Ton @ 40-60 Degree F Chilled water, Trane Absorption Chiller, Model ABSC 750, Serial Number L93J09295, single stage. Operates on Nominal 12 psig steam or Nominal 270 degrees F hot water. These chillers use 18 pph of low pressure steam per ton of cooling.(13,500 pph of 9-12 psi steam) Utility rate is controlled by the leaving chilled water set point. Chilled water flow rate is up to 1766 gpm, and can be set from 40-60 degrees F. These absorption chillers use water as the refrigerant and Lithium Bromide as the absorbent. Both of the items are non- toxic. Main components of the chiller are the generating section, the condenser, the evaporator, and the absorber. Additional components include the heat exchanger, solutions pumps, control valves and electronic microprocessor controls. These models use the Trane single pump system with 3 impellers, 15HP 3/60/460 volt, FLA 12A, max fuse size 45 a, purge pump 1/4 HP, 1/60/115 volt.
35 Items ReturnedGo To Page: 12

Add Checked to Quote
 Add to Quote Before Changing Page

  

IPP Sales Contacts Minimize

Keith West
Global Sales
Email Keith
Direct: 1-609-838-5931
Office: 1-609-586-8004

Amanda Vagell
Global Sales and Israel
Email Amanda
Direct: 1-609-838-5929
Office: 1-609-586-8004

Patti Buchman
Global Sales
Email Patti
Direct: 1-609-838-5928
Office: 1-609-586-8004

Brian Brink
Global Sales
Email Brian
Direct: 1-609-838-6041
Office: 1-609-586-8004

Western Europe
Sales & Acquisitions
France, Belgium, Germany, Luxembourg, Netherlands, Denmark, Switzerland, Liechtenstein

Regina Zarmer
Click to email Regina
Office: 49-306-594-2445
Mobile: 49-172-313-8439

UK, Scandinavia, Africa, Southern Europe, Mid East (except Israel)
Sales & Acquisitions

Greenland, Monaco, San Marino, Italy, Malta, Andorra, Gibraltar, Greece, Finland, Norway, Sweden, Iceland, Faroe Islands, Turkey, Cyprus

Office: 44 (0)1642-367-910
Fax:    44 (0)1642-367-920

Jo Petrie
Click to email Jo
Direct: 44 (0)1642-367-913 Mobile: 44 (0)7770-748-884

Nicola Douglas
Click to email Nicola
Mobile: 44 7940 981 681

Eastern Europe, Western Asia Sales & Acquisitions
Czech Rep, Slovakia, Slovenia, Poland, Romania, Hungary, Ukraine, Lithuania, Bulgaria, Bosnia, Albania, Croatia, Serbia, Belarus, Estonia, Latvia, Macedonia, Moldova, Russia, Georgia, Bashkortostan, Kazakhstan, Kirghizia, Krygyzstan, Tajikistan, Turkmenistan, Uzbekistan, Armenia, Azerbaijan 

Bohumil Cuta
Click to email Bohumil
Office: 42-054-821-6680
Mobile: 42-060-273-7517

Central & South America, Caribbean Sales

Office: 1-609-586-8004
Elisa Lucumi
Click to email Elisa
Direct: 1-609-838-5927

Edis Castillo
Click to email Edis

 

     

Home | About Us | News | Contact Us | Equipment Search | Plant Search | Industrial Real Estate | Sell to IPP | Mailing List | IPP's eBay Store | PDF Downloads | Events
  Copyright 2002-2014 International Process Plants   Terms Of Use  Privacy Statement   
The European Petrochemical Association International Fertilizer Industry Association Institute of Scrap Recycling Industries, Inc. National Demolition Association National Demolition Association Turnaround Management Association Association Memberships