Chillers
|
 |
|
|
|
203635
300 ton chiller designed to cool 40% Ethylene Glycol from 32 degrees F to 14 degrees F. Low temperature chiller skid manufactured by Frick (York International.) Frick # 292388. Designed to use R-22. This a complete skid mounted chiller including condenser, evaporate, and two (2) Frick RWBII-100E rotary screw compressors, designed for 350 psig high side, 300 psig low side, and each rated 298 BHP. Compressor A is a Model TDSH193S1746C, Ref. NH3/R22, Rated for max. speed of 4500 rpm. Max. Design pressure 362 psi. Compressor B is RWB II 100/100, serial # 30580MEMPTHAR2, ref. R22, Maximum speed is 3600 rpm. Max design pressure is 300 psi. Drivers are Reliance XE Premium Efficiency, 350 HP, 3570 rpm. ID # 1MAE73017. Rated for 3 ph, 60 Hz, 460 volts. Frame type 449TS. Comp. "A" 37490 Hours, Comp. "B" has 38193 hours. Evaporator is by Frick, NB # 109666, shell rated for 300 psi at 200 degrees F, Tubes not code. Built in 1993., Condenser is manufactured by Refrigeration Valves and systems, NB # 5428, Shell rated for 150 psi at 200 degrees F, tubes rated for 150 psi at 200 degrees F, Serial # 92945, Built 1993. Twin oil coolers are Frick NB # 109367, shell rated for 300 psi at 200 degrees F, tubes rated for 300 psi at 200 degrees F. Built in 1993. Complete skid mounted system with all piping and accessories. Controls are electronic, RWB II Plus, one for each compressor. Mounted in a stainless steel enclosure. Spare compressors are available.
Read More...
|
| |
|
|
|
|
|
|
|
|
Used Boilers
Used Hot Oil or Thermal Fluid Boilers
Hot Oil or Thermal Fluid Boilers often are used to heat equipment in process plant applications. High temperatures can be reached using thermal fluid boilers vs steam.
The hot oil or thermal fluid is heated by passing the thermal fluid around electric heating elements. On lager units, the thermal fluid is passed though tubes or coils that are heated on the outside by a flame created by burning fuel.
The different fuels that are burned include Oil (typically # 2 or # 6 grade), Natural Gas, and combinations of Oil and Gas.
The typical configurations of hot oil heater/hot oil boilers are horizontal, vertical, or packaged design.
Used Steam Boilers
IPP offer many different types of Steam Boilers including Fire Tube, Economizers, Hot Water Heaters, Waste Heat, and Water Tube Boilers.
Boilers are used to create steam or hot water for process plant applications. Certain plants use steam or hot water (vs. a thermal fluid) to heat their reactors and heat exchangers for cooking their products. Boilers are also crucial in Power Generation plants or Co-Generation Plants where you use steam turbines to generate electricity.
The steam or hot water is heated by passing water either through tubes (Water Tube) or around tubes that are heated by a flame (Fire Tube and Scotch Marine). The flame is created by burning some type of fuel. The different fuels that are burned include Coal, Pulverized Coal, Oil (typically # 2 or # 6 grade), Natural Gas, Waste Heat, or combinations of Oil and Gas.
There are also steam boilers that heat the water by using the waste heat generated from another process in the plant to heat the water to create steam. In the trash industry there are "Trash to Steam" boilers that burn trash to generate the steam.
The typical configurations of steam boilers are water tube and fire tube. This indicates whether the heat source surrounds the tubes and the water is in the tubes (water tube), or the heat source goes through the tubes and the water surrounds the tubes (fire tube). Many smaller boilers are the fire tube type, while many very large boilers are the water tube type.
IPP has a large inventory of Used, Unused, and Reconditioned oil heaters and boilers as well as boiler accessories. Manufacturers include: A O Smith, Adamson Global Technology, Babcock & Omnical, Babcock & Wilcox, Burnham, CEMLINE, Challenger, CLEAVER BROOKS, E. Keeler, Electro, ELECTRO STEAM, First Thermal, Foster Wheeler, Fulton, GEKA, H K D, HEATEFLEX, Holman, Hurst, Kam, KAM THERMAL, Keeler, Kewanee, Loveco, MIURA, Nebraska, Newpoint, Parker, Patterson Kelley, Pfaudler, RAYPACK, Sellers, SELLERS BOILER, Stokes, Superior, Sussan, Syltherm, Thies/Funke, Triple S, Triple S Dynamics, Vapor, Vapor Power International, Viessman, VIESSMAN ATOLA, VIESSMAN HORICELL .
|
|
Enter a product number or part of its description below and click SEARCH
OR
Now choose a product sub group (if any are present below)
| 81 Items Returned | Go To Page: | 1 | 2 | 3 | 4 | 5 |
|
| | | Stock Number | Product | Sub Group | Capacity | Description |
|
|
| 13918 | BOILER | STEAM | | 687,000 BTU input @ 125 psi HW, Cleaver Brooks fire tube steam boiler. Mdl CB900112, SN L46804. Natural gas or oil fired. 32.3 gph. |
|
|
| 17432 | BOILER | STEAM | 18200 | ****18,200 lbs/hr @ 120 psi, high voltage electrode steam boiler. Mfd by Hydro Steam Ind, Model BBJ-2C, SN 61781, NB #11769, blt 1985. Rated 12.2 KV. Complete unit w/5000 KVA isolation transformer; 26,000 lb/hr deaerator; (2) 20 HP feedwater pumps; water softener. |
|
|
| 22049 | BOILER | HOT OIL | 6 | 6.55MM Hy-Way hot oil heater. Mdl 67CFH, SN 2656. Hev-E-Oil burner, mfd by Industrial Engineers, Mdl AM5CM, SN G8872. Fires #6 fuel. |
|
|
| 43274 | BOILER | HOT OIL | 10 | 10.0MM BTU input portable Parker thermal liquid heater system. Serial # 40225 and 40226. Unit has (2) trailer mtd Mdl HT-5000 boilers. Each rated ASME 125 psi, 5.0MM BTU output. Propane fired. Furnished fully assembled in special insulated cabinet w/burner and operating controls mtd and electrically wired in compliance w/normally accepted FM standards. Both unit mtd in tandum on 40' trailer for portable use. |
|
|
| 43354 | BOILER | HOT OIL | 2 | 1.75MM BTU/hr Struthers Wells direct fired Dowtherm heater w/economizer. SN 58F-6261, NB #47. Int rated 200 psi @ 750 deg F. 5'6" OD x 13' str side. Refractory lined, 4'6" ID. 228 sq ft surface area, 18 pass, with 4 1/2" dia vert tubes. Has John Zinc type DBA-14 gas or oil fired burner mtd thru btm. Mtd on (4) legs. 12" dia x 15' long stack. W/Dean Bros 304SS circulating pump, 300 gpm @ 105'TDH (no motor). Economizer is mfd by Chanute, 403 sq ft. Rated 200 psig @ 750 deg F. (18) 4 1/2" dia x 4'10" long CS tubes, NB rated. |
|
|
| 70330 | BOILER | STEAM | | 360 gpm, 150 psi water pressure, Parker hot water boiler. Mdl T-4600, SN 22441, NB #22441. 573 sq ft heating surface. Natural gas fired. 4,600,000 BTU/hr input; 3,680,000 BTU/hr output, 80% efficiency. Capacity 360 gpm, 20 deg F temp rise. 4" inlet, 5" outlet. |
|
|
| 76234 | BOILER | HOT OIL | 14 | 84,500 BTU/hr, 26 KW, Youngtown Miller hot oil system. SN HT1068, Type HT26-1S. Rated 35 gpm, rated temp 500 deg F to 700 deg F. Unit has (3) electric heating elements, Class 1, Group D. W/expansion tank mtd over cabinet. Cabinet size 32" wide x 36" deep x 70" high. Complete unit w/circulating pumps. |
|
|
| 78338 | BOILER | HOT OIL | | Sterlco 9 KW/zone water dual zone temp control unit. Mdl M8422-GX, SN 44663, blt 1983. Rated at up to 300 deg F. Has 3 HP TEFC motor/pump. Electricals: 3/60/460 volt. |
|
|
| 78514 | BOILER | HOT OIL | 0 | Approx 100,000 BTU/hr (30 KW) CS hot oil heater. Mfd by Patterson Ind, SN 65-1507, NB #1262. 18" dia x 30" str side horiz CS tank, dish head, w/(2) 15 KW electric heating elements mtd in 6" flange nozzle in each head. With 3/4" high pressure level indicator. Tank rated for 100 psi @ 700 deg F. Shell 5/16" thick, heads 1/4". Openings: top 1-1 1/2", 1-1", 3-3/4"; 1" btm outlet. |
|
|
| 83317 | BOILER | HOT OIL | 9 | 9.0MM BTU/hr, Loveco CS direct fired gas oil heater. SN C-79-131, NB #2, Mdl NDEO686-18EK, blt 1980. Max allowable working pressure 150 psi @ 700 deg F. Heating surface 3180 sq ft. Heating coil openings: 2-4" inlets, 2-4" outlets. W/Bloom gas burner, SN PE-0679-15, Type 1026-100. Includes gas train panel and controls. Oil circulating pump not included. Skid mtd. |
|
|
| 83879 | BOILER | HOT OIL | 1 | 1,024,000 BTU Gessner exp-proof hot oil heater. Mfd by Youngstown-Miller, SN HT-1381, Mdl HT-3001X. 300 KW, 3/60/480 volt, 392 amps. Unit has (3) 100 KW heating columns. Total oil capacity 100 gal. 1,024,000 BTU Gessner exp-proof hot oil heater. Mfd by Youngstown-Miller, SN HT-1381, Mdl HT-3001X. 300 KW, 3/60/480 volt, 392 amps. Unit has (3) 100 KW heating columns. Total oil capacity 100 gal. |
|
|
| 87320 | BOILER | STEAM | | 150 psi, Bryan Flextube water tube boiler. Mdl CL270-S-150-FD0, Bryan #890988, SN 67881, NB #27374, blt 1990. 322 sq ft heating surface. Oil fired. Burner mfd by Gordon-Platt, Type R10.9-0-10. Firing rate max 19.3 gph, min 12.0 gph. 2.7 million BTU/hr. Input max 1350 MBH, min 2700 MBH. 3/60/460 volt motor. Control 1/60/120. Cabinet enclosed, skid mtd. W/complete controls. W/40 gpm @ 125'TDH, 316SS Peerless pump, 3 HP. |
|
|
| 97172 | BOILER | STEAM | 50000 | 50,000 lbs/hr @ 260 psi, Cleaver Brooks water tube boiler. Mdl D-76, SN 67017, NB #44150, Unit #WL-2821. Design pressure 260 psi. Burner supply pressure 100 psi. Combination gas and oil fired. #6 fuel oil. 428 gph; propane gas 140 scfh. Heating surface: boiler 3595 sq ft; waterwall 634 sq ft. Burner mfd by Cleaver Brooks, Type WT600X-CN3, SN WL-2821. Firing rate input 72.125MM BTU/hr. 3/60/460 volt, UL label. |
|
|
| 99101 | BOILER | STEAM | 25000 | 25,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34309. Twin burners mfd by Hanworthy Ltd, Mdl AW1-35. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15.6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 7.5 HP forced induction blowers. Has control panel. |
|
|
| 99102 | BOILER | STEAM | 25000 | 25,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34310. 220 psi max. Twin burners mfd by Hanworthy Ltd, Mdl AW1-35. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15'6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 7.5 HP forced induction blowers. Has control panel. |
|
|
| 99103 | BOILER | STEAM | 25000 | 25,000 lbs/hr, 220 psi, Danks of Nethertow heavy oil fired, fire tube steam boiler. SN 34311. Twin burners mfd by Hanworthy Ld, Mdl AW0-30. 1st pass: 2528 sq ft (235 sq meter) heating surface. (178) 3 1/2" (88.9mm) OD w/(46) stay tubes 15'6" (4737mm) long. 2nd pass: 4552 sq ft (516 sq meter) heating surface. (322) 3" (76.1mm) OD w/(88) stay tubes 18' long. Mtd on welded saddles. Has (2) approx 10 HP forced induction blowers. Has control panel. |
|
|
| 99104 | BOILER | STEAM | 28000 | 28,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN 6606. 220 psi max. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184) 3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower. |
|
|
| 99105 | BOILER | STEAM | 28000 | 28,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN 6607. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184) 3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower. |
|
|
| 99106 | BOILER | STEAM | 28000 | 28,000 lbs/hr, 220 psi, NEI Cochran Ltd twin flue coal master water tube boiler. SN CM7580. 220 psi max. 1st pass: (44) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (184)_3" (76mm) OD x 4mm thick x 14' (4200mm) long. Total 2645 sq ft heating surface. 2nd pass: (26) 3" (76mm) OD x 10mm thick x 18' (5500mm) long and (166) 3" (76mm) OD x 4mm thick x 18' (5500mm) long. Total 2713 sq ft heating surface. Has 4' wide x 12' long coal feeder, driven by approx 1 HP varispeed motor. Has (2) 4.2 HP (5.5 KW) belt driven forced draft blowers and (1) 25 HP (37 KW) belt driven induced draft blower. |
|
|
| 100180 | BOILER | STEAM | 5021 | 5,021 lbs/hr @ 150 psi steam and water, 150 HP, Kewanee fire tube boiler. Type #H35-150-05, SN P7047. 750 sq ft heating surface. 6' x 12' firing chamber area. Max working pressure: steam 150 lb. Oil fired. Firing range: oil 14-56 gpm; max firing rate: 6278 MBH. Safety valve capacity 6000 lb/hr. Cust order #432245, UL listed #P338953. Burner mfd by Ray Burner Co, SN 305563, Type PAECP-144, Size 150. 3/60/208 volt. 2.10 to 6.28 million BTU. UL listed #P74362. Unit shares (3) water feed tanks/(3) pumps w/stk #100181. Tanks: 300 gal CS (mtd above pumps); 70 gal and 9 gal (cut loose). Pumps: (2) working @ 22 gpm, (1) switchable backup for #1 and #2 boilers. |
| 81 Items Returned | Go To Page: | 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
IPP Sales Contacts
|
 |
|
Keith West Global Sales KeithW@ippe.com +1 609 838 5931 | Amanda Vagell Global Sales AmandaV@ippe.com +1 609 838 5929 | Patti Buchman Global Sales PattiB@ippe.com +1 609 838 5928 | Ray Wagner Global Sales RayW@ippe.com +1 609 838 6043 | Regina Zarmer Europe Sales & Acquisitions ReginaZ@ippe.com +49-306-594-2445 Office +49-172-313-8439 Mobile +49-30-6594-2448 Fax | Jo Petrie, Sales Engineer UK, Scandinavia, Spain, & So.Africa jop@ippe.com +44 (0)1642 367 910 Office +44 (0)1642 367 913 Direct +44 (0)7770 748884 Mobile +44 (0)1642 367 920 Fax | Bohumil Cuta, E. Europe Sales & Acquisitions BohumilC@ippe.com +42-054-821-6680 Office +42-060-273-7517 Mobile +420-5-481-22240 Fax | Elisa Lucumi Central & So. America Sales ElisaL@ippe.com +1 609 838 5927
|
|
|
|
|
|
|
|