| 13275 | BOILER | STEAM | 10350 | 10,350 lbs/hr @ 15 psi, Amer Standard fire tube boiler. Mfd by Kewanee/American Standard, Type LS300G, SN 0540. 300 HP. Water pressure 30 psi. Gas fired; controls 3/60/460 volts; forced draft fan; Type KS burner, Mdl KS10.0-2415G, SN 419856, 460 volt, 17 amps. Firing range 2500 to 12600 MBH, 12554 max range, UL listed. W/control panels. All skid mtd. |
|
|
| 17360 | BOILER | STEAM | 0 | 100 psi Electric heated steam generator. Mfd by Electric Steam Generator Corp (Michigan City,IN), Mdl 100A2/1, SN 78461, NB #54330. 220 volts. 15KW, 51000 BTU, 45 amps. Has small pump driven by 1/4 HP, 1/60/115/230 volt, 1725 rpm motor. |
|
|
| 17432 | BOILER | STEAM | 18200 | ****18,200 lbs/hr @ 120 psi, high voltage electrode steam boiler. Mfd by Hydro Steam Ind, Model BBJ-2C, SN 61781, NB #11769, blt 1985. Rated 12.2 KV. Complete unit w/5000 KVA isolation transformer; 26,000 lb/hr deaerator; (2) 20 HP feedwater pumps; water softener. |
|
|
| 22049 | BOILER | HOT OIL | 6.5MM | 6.55MM Hy-Way hot oil heater. Mdl 67CFH, SN 2656. Hev-E-Oil burner, mfd by Industrial Engineers, Mdl AM5CM, SN G8872. Fires #6 fuel. |
|
|
| 22130 | BOILER | HOT OIL | 1.2MM | 1.2MM BTU Dowtherm vaporizer. Mfd by Foster Wheeler, SN 23-584, NB #5945. Rated 150 psi, 435 sq ft. Chamber is refractory lined. W/Mdl SBI-2010 Hauck blower w/10 HP, 3/60/230/460 volt, 3500 rpm motor. |
|
|
| 32936 | BOILER | STEAM | 5175 | 5,175 lbs/hr, 150 psi, 150 HP Kewanee firetube boiler. NB #14520, Cat #HT150, Series 1X. Refractory lined fire box. Unit is 18'6" long x 8'8" wide x 10'1" high. |
|
|
| 33205 | BOILER | HOT OIL | 3.7MM | ****3.75MM BTU/hr (2MM min) Union Iron Works hot oil boiler. SN 22181, NB #3261. Int rated 150 psi @ 750 deg F. North American natural gas premix burner. Gas pilot ignition. Gas pressure being boosted by North American turbo blower, Mdl 306G-C1-3/4, rated 300 cfm. Direct driven by 3/4 HP, 3/60/208/220/440 volt, 3450 rpm. Secondary air supplied by 3/4 HP, 3/60/220 volt, 3515 rpm motor. Flame safety by Flame King. |
|
|
| 33343 | BOILER | HOT OIL | 5.7MM | ****5.75MM BTU/hr @ 150 psi, 750 deg F, Process Combustion hot oil heater. Mdl EPE-0676-33, SN 1466-045. Horiz design. Oil fired. |
|
|
| 41443 | BOILER | HOT OIL | | 34 KW Hynes electric hot oil heater. 440 volts. SN H5526. Has 36" wide x 5' long heating box. UL enclosures on control box. Skid mtd design. |
|
|
| 43274 | BOILER | HOT OIL | 10 | 10.0MM BTU input portable Parker thermal liquid heater system. Serial # 40225 and 40226. Unit has (2) trailer mtd Mdl HT-5000 boilers. Each rated ASME 125 psi, 5.0MM BTU output. Propane fired. Furnished fully assembled in special insulated cabinet w/burner and operating controls mtd and electrically wired in compliance w/normally accepted FM standards. Both unit mtd in tandum on 40' trailer for portable use. |
|
|
| 43354 | BOILER | HOT OIL | 1.7MM | ****1.75MM BTU/hr Struthers Wells direct fired Dowtherm heater w/economizer. SN 58F-6261, NB #47. Int rated 200 psi @ 750 deg F. 5'6" OD x 13' str side. Refractory lined, 4'6" ID. 228 sq ft surface area, 18 pass, with 4 1/2" dia vert tubes. Has John Zinc type DBA-14 gas or oil fired burner mtd thru btm. Mtd on (4) legs. 12" dia x 15' long stack. W/Dean Bros 304SS circulating pump, 300 gpm @ 105'TDH (no motor). Economizer is mfd by Chanute, 403 sq ft. Rated 200 psig @ 750 deg F. (18) 4 1/2" dia x 4'10" long CS tubes, NB rated. |
|
|
| 47882 | BOILER | HOT OIL | 4.0MM | 4.0MM BTU, Parker hot water heater. Mfd by Parker Boiler, NB #22256, Mdl #5000. Rated 150 psi w/660 sq ft heating surface. Natural gas fired. Unit has air cooled oil cooler. |
|
|
| 47883 | BOILER | HOT OIL | 4.0MM | 4.0MM BTU, Parker hot water heater. Mfd by Parker Boiler, NB #22255, Mdl #HT5000. Unit rated 150 psi w/660 sq ft heating surface. Natural gas fired. Unit has air cooled oil cooler. |
|
|
| 70330 | BOILER | STEAM | | 360 gpm, 150 psi water pressure, Parker hot water boiler. Mdl T-4600, SN 22441, NB #22441. 573 sq ft heating surface. Natural gas fired. 4,600,000 BTU/hr input; 3,680,000 BTU/hr output, 80% efficiency. Capacity 360 gpm, 20 deg F temp rise. 4" inlet, 5" outlet. |
|
|
| 76234 | BOILER | HOT OIL | 14 | 84,500 BTU/hr, 26 KW, Youngtown Miller hot oil system. SN HT1068, Type HT26-1S. Rated 35 gpm, rated temp 500 deg F to 700 deg F. Unit has (3) electric heating elements, Class 1, Group D. W/expansion tank mtd over cabinet. Cabinet size 32" wide x 36" deep x 70" high. Complete unit w/circulating pumps. |
|
|
| 76671 | BOILER | HOT OIL | 0 | 500,000 BTU/hr @ 750 deg F, 146 KW, hot oil heater. Mfd by Konus-Kessel, Mdl KVO-16/25, SN 435109, Order #118752000. 163 psi @ 750 deg F. 259 gal capacity. Maxon Mdl 408M burner package, rated 600,000 BTU/hr. Maxon combustion air fan with 3/4 HP motor. Main circulation pump, Dickow NML cast iron, 56 gpm, 45 psi @ 730 deg F, w/10 HP, 3500 rpm motor. Recirculation pump, Dickow NKL, cast iron, 20 gpm, 60 psi @ 630 deg F w/5 HP, 3500 rpm motor. System requires 116 gal CS expansion tank, rated 150 psi @ 650 deg F. |
|
|
| 76751 | BOILER | HOT OIL | 1 | 793,600 BTU/hr gas fired heater unit. Mfd by Krauss Maffei. Max operating pressure coils 180 psi @ 660 deg F. Gas burner for natural gas. Modulating range 1:3. Heat release 561,500 BTU/hr. Primary pump 100 gpm @ 100'TDH. Expansion tank 70 cu ft. |
|
|
| 78338 | BOILER | HOT OIL | | Sterlco 9 KW/zone water dual zone temp control unit. Mdl M8422-GX, SN 44663, blt 1983. Rated at up to 300 deg F. Has 3 HP TEFC motor/pump. Electricals: 3/60/460 volt. |
|
|
| 78514 | BOILER | HOT OIL | 0 | Approx 100,000 BTU/hr (30 KW) CS hot oil heater. Mfd by Patterson Ind, SN 65-1507, NB #1262. 18" dia x 30" str side horiz CS tank, dish head, w/(2) 15 KW electric heating elements mtd in 6" flange nozzle in each head. With 3/4" high pressure level indicator. Tank rated for 100 psi @ 700 deg F. Shell 5/16" thick, heads 1/4". Openings: top 1-1 1/2", 1-1", 3-3/4"; 1" btm outlet. |
|
|
| 83317 | BOILER | HOT OIL | 9 | 9.0MM BTU/hr, Loveco CS direct fired gas oil heater. SN C-79-131, NB #2, Mdl NDEO686-18EK, blt 1980. Max allowable working pressure 150 psi @ 700 deg F. Heating surface 3180 sq ft. Heating coil openings: 2-4" inlets, 2-4" outlets. W/Bloom gas burner, SN PE-0679-15, Type 1026-100. Includes gas train panel and controls. Oil circulating pump not included. Skid mtd. |