Need Help? or Have something for sale? USE THIS FORM:
|
|
|
|
|
|
|
|
Chillers
|
 |
|
|
|
207381
165 Ton @ -32 degrees F, Dunham Bush horizontal screw refrigeration package. Water cooled design. R22 Refrigerant. Compressor Model 2515/5.40, Horizontal Rotary Screw, rated 3550 RPM, direct coupled to a Siemens 600 HP, 3/60/460 volt motor. Evaprator is a 2 pass, 24" diamter x 176" long, (288) 3/4" x 0.049 x 176" long trufin tube carbon steel tubes. Condensor is a 2 pass, 18" diameter, x 153" long, (228) 3/4" x 0.028" x 153" long tubes, trufin copper tubes. All skid mounted with lubeoil system, and digital control panel. With Westinghouse starter WYE-Delta Closed Transition, NEMA-1 encloser floor mount. Unit dimensions are 212" L x 8"W x 116" H, 24,500 lbs.
Read More...
|
| |
|
|
|
|
|
|
|
|
Used Filters
Filtration is the separation of a fluid-solids solution involving the passing of this mixture through a porous barrier which retains most of the solid particulates contained in the mixture. The various terms used in filtration processes include: Media – the filtration cloth or barrier to collect the solids, Liquor – the solution containing the liquid and solids, Filtrate – the liquid that has been filtered clear, Cake – the solids filtered out of the liquid, Polishing – the removal of the last bit of solids for a finished liquid product, Washing – pumping water or a wash liquid over the cake, Pre-coat – coating the filter cloth with a material like diatomaceous earth to aid in the filtering.
The liquor is either pushed through the filter under pressure or pulled through the filter under vacuum. The types and configurations of filters vary widely; each has its own method of filtering, its own method of discharging the filtrate and discharging the cake. Depending on the product, sometimes the filtrate is the desired product and other time the cake is the desired product.
Filters are measured by the square foot surface area available for filtering, and the cubic foot cake capacity.
Type of Filters:
- Plate and Frame Filter Press – this is an assembly of plates covered with a filter cloth and frames designed to collect the cake, held together in a press with that has a head plate and tail plate – the press is closed by a hydraulic pump, or manually in small presses. The plates and frame can be made of many types of materials, polypropylene is popular. Many times the press has “recessed plates” where two plates form a cavity for collecting cake eliminating the frame. Filter presses must be opened and the plates separated to remove the cake.
- Pressure Filters – These are batch filters that push the liquor through the filter under pressure. Once the cake capacity is reached the cake must be removed before you continue the process. All pressure filters consist of a vessel with internal filter plates or cloths.
- Basket, Candle, & Cartridge filters - This type of filter has a tank with an internal basket with a cloth bag, or filter cartridges, mounted inside the tank.
- Vertical Tank with Horizontal plate filters - Once the plates are full of cake the cake must be removed. In smaller filters like a Sparkler filter, the plate bundle is remove manually, in larger filters like a Shenk or Funda filter the plate bundle is rotated at a high rpm to use centrifugal force to throw the cake off the plates and remove cake from the bottom of the tank.
- Horizontal Tank Vertical plate filters – the cake can be removed by shaking the plates, spraying the plates with high pressure water, or scraping the cake off as the plate bundle rotates.
- Vacuum filters – These include rotary drum filters and horizontal belt filters. Both are continuous operations.
- Rotary Drum filters – these are horizontal drums with perforated exteriors covered with a filter cloth and internal vacuum pipes that are designed to be partially submerged in a trough of liquor. The internal vacuum pipes create suction on the outside of the drum. As the drum rotates the liquor is pulled through the filtrate cloth and the cake is form on the outside of the drum. Before the cake dips back into the trough it is removed from the drum by a scraper or belt discharge.
- Horizontal Belt filters – The liquor is spread onto one end of a horizontal perforated belt covered with a filter cloth. A vacuum is pulled under the belt creating suction on top. As the product is conveyed along the moving belt the filtrate is pulled through the belt perforations, leaving the cake on top. When the cake reached the end of the belt it basically drop off or is scrapped off the filter cloth.
- Pan filters – Like a belt filter with a moving filter cloth and suction underneath, this filter replaces the belt with a series of vacuum pans that extract the filtrate while the cake is conveyed along the filter cloth.
- Rosenmund Type – The major manufacturers of this type of filter are Cogiem and Rosenmund. Also known as Filter/Dryers and Nutche filters. This type of filter is typically pressure and vacuum rated internally, heated with a jacket, and has an agitation system that double as a cake discharge screw, and for added drying, the shaft of the agitator can be cored for heating and cooling. Depending on the process this type of filter can take the place of a reactor, a filter, and a dryer, all in one machine. The basic design is a large diameter tank, with a screen in the bottom head, top mounted agitator drive that can raise and lower the internal blades during different cycles. When the process is finished the agitator is lowered to scrape along the filter screen, a cake discharge valve is opened, the agitator scrapes the cake out of the filter/dryer. The newer machines have a removable bottom head so the filter screens can be removed and the bottom head cleaned without any type of tank entry. Filter/dryers are measured by the Square Meter of filter screen area.
- Tower Filters – Similar to a filter press in filtration techniques. The tower press has horizontal plates with a continuous cloth woven in and out of the plates. During filtration the plate stack is closed and during discharge the plate stack is opened and the cake is conveyed out of the pres by the filter cloth. Eliminates the manual labor use to clean filter presses.
IPP carries an extensive inventory of used, unused and reconditioned filters in stock including filters manufactured by: 3-L, 3V COGEIM, Acme, ACME INDUSTRIAL, Alar, Alar Auto, Alar Engineering, Allegheny Bradford, Alsop, AMERICAN FILTER, AMETEK, AMF, Amicon, Andritz, Apache, APV, Ashbrook, Aurora, AURORA FILTERS, Avery, BAEUERLE & MORRIS, BAEUERLE & MORRIS INC, Baeurle & Morris, BALSTON FILTER, BIRD, BIRD YOUNG, Cambridge, CARLSON, Carter Day, Chemap AG Funda, Chemap Ltd, CHICAGO BOILER, Chicago Boiler Co., Choquenet, Clow, Cogeim, COGEIM SPA, Comber, COMER, Commercial, Commercial Filter Corporation, COMMERCIAL FILTERS, COMMERCIAL FILTERS CORPORATION, CP 1200 F, CULTER, CUNO, CUNO/MARTIN PETERSON, CUTLER METAL PRODUCT, DELAVAL, Dorr Oliver, Durco, DURCO ENZINGER, Durco/Enzinger, Durion, Duriron, Edward & Jones, Eimco, ENVIRONMENTAL TECH, Enviroquip, Ertel, ERTEL/ALSOP, EUROFILTEC, Extract Technology, Filler Specialties, Filter Specialists, Filterdyne, Filterite, FILTRATEC, Filtration & Separat, Filtration & Separation, Filtration Eng., Filtration Engineers, Filtration Systems, Filtroba AG, Filtrox-Werk, Flexline, Flow Trend, FRANTZ FERRO, FSI, Fulflo, GAF, GELMAN SCIENCES, GENERAL FILTRATION, Guedu, Harmsco, Haward, Hercules, HERCULES FILTER, Hoechst, HOESCHT, Hovex-Holland, Ideal Welders Ltd, Idrex, IMECA, Industrial, Industrial Filter, International, Jaygo, JWI, Ketema, KETEMA NIAGARA, KLAMPRESS 8/90, Klein, Komline Sanderson, Lanco, Larox, Larox-Pannevis, Lee Ind, LEE INDUSTRIES, LS10-BO-6, MECHANICAL FILTRATION, MEMTEC, Met-Chem, Millipore, Netzsch, Niagara, NIAGRA, Nivoba, Northland, NORTHLAND STAINLESS, NUTSCHE, Oberlin, OPF 4, OPF-12, OPF-4, Padovan, Padovan Taylo, Pall Corp, PALL TRINITY, Pannevis, Parker, PARKER HANNIFIN, PARKER/FULFLO FILTER, Parkson, Passavant, Perrin, Powder Systems, POWDER SYSTEMS LTD, Pressofiltro, Quantum Technologies, Romicon, Ronningen, RONNINGEN PETTER, RONNINGEN-PETTER, RONNING-PETTER, Rosedale, ROSEDALE PRODUCTS, ROSENMUND, RP Products, RT 0575, RUSSELL FINES, Russell Finex, Saltec, Sartorius, SARTORIUS STEDIM, Schenk, Seitz, SEITZ ENZINGER, Seitz Orion, Seitz Wega, Sernagiotto, Shriver, Sietz, Sietz Enzinger Noll, SLF Inc, SPARKLER, Sparkler Filter, SPARKLER FILTERS, Sperry, Standard, Star, Star Systems, Steri Technologies, Stossier, STRAINRITE, Strainrite Inc, STRAINRITE INC., Strassburger, Sweco, T. SHRIVER & CO. INC, Technical Fabricator, Thompson, Trent, TRI-CLOVER, Triton, US Filter, USF Filtration, Valex, Velo, Vernay, Vevey, Von, Von Roll, Waterlink Lanco, Westech, WESTECH ENGINEERING, William Sprinkman, WWE, Yabuta, Zurn, ZURN INDUSTRIES, Zwag .
|
|
IPPE Equipment Seach Enter a product number or part of its description below and click SEARCH
Finally, you may filter the results based on capacity below
| 14 Items Returned | Go To Page: | 1 |
|
| | | Stock Number | Product | Sub Group | Capacity | Description |
|
|
| 36173 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | | ****1,000 gpm reverse osmosis, boiler feed water system. System includes: (P107) feed pump, 1500 gpm @ 260' TDH centrifugal pump, split case, driven by 200 HP, 3/60/460 volt motor. (P850) standby supply pump, cast iron, 1500 gpm @ 260' TDH, 150 HP, 3/60/460 volt, 1770 rpm. (E850) RO feedwater preheater, 1398 sq ft, 304SS tube side, CS shell, 2 pass tube side, single pass shell, 1308 gpm 32 deg F inlet, 40.1 deg F outlet. (E851) RO feed water final heater, 1471 sq ft, 304SS tube side, CS shell, single pass shell side, 248 gpm, 40.1 deg F inlet, 231 deg F outlet tube side. (X850H/J) sulfuric acid metering pumps, 1/3 HP, 3/60/460 volt, (1) active, (1) standby. (X850F/G) (2) epoxy lined cartridge filters, rated 150 psi, 10 microns. (850M/N) (2) hexametaphosphate metering pumps, 1/3 HP, 3/60/460 volt. (X850R) cleaning solution pump, 327 gpm @ 65 psig, 3x2-8, 25 HP, 3/60/460 volt, 3600 rpm, UL label, w/mech seal. (P851A/B) (2) booster pumps, 316SS, 2-stage double suction, 6" x 4", side suction and discharge, horiz splitcase, 1250 gpm @ 1060'TDH, 3550 rpm, (1) pump requires 500 HP, 3/60/2300 volt motor, (1) pump turbine driven by 492 HP, 650 psig @ 700 deg F, 3" steam inlet, 200 psig, 8" steam exhaust, 48 lbs/HP steam rate, 3550 rpm. (X850A/B/C/D/E) (5) reverse osmosis modules, 4-active, 1-standby. Each module consists of 2-stages, (9) vessels in 1st stage, (4) in 2nd stage. Each vessel 8" dia x 20' long (no membranes). |
|
|
| 42805 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | | 12-module Mdl 36 DDS(Denmark) ultra filtration system. Mdl UF-Plant, blt 1986. Sanitary construction. System has (12) modules w/Mdl 38L plates w/.4mm channel height suited for low viscosity. Plates have Type TR61 membrane. Each module has (2) cooler/heat exchangers w/total of (24) for the system. Each exchanger is 21.5 sq ft (2 sq meters), rated 87 psi (6 bar). Shell and tube design, all 304SS construction. 3" inlet and 3" outlet. |
|
|
| 70700 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | | Osmonics Inc 304SS reverse osmosis system. SN 90-C-222011A, Mdl 10BQ891130-HP-304SS. Unit has (3) 8" dia x 11' long horiz tubes. Skid mtd w/19 sq ft Superchanger; filter tank; (2) 10 HP Tonka-flo pumps. W/unit are (2) 4" dia tubes for using instead of 8". |
|
|
| 72159 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 53 | 53 sq ft Continental ultra filtration system. SN 2211681930. Has (7) 3" dia Romicon Mdl #GM80, 20ml fiber cartridges. Unit rated for 25 psi @ 45 deg C. Has all controls and 1 HP Price circulation pump. Mtd on skid. |
|
|
| 95442 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 450 | 450 sq ft Romicon ultra filtration membrane filter system. Unit has (18) 25 sq ft filter membranes, 3" dia x 42" long, Type PM50, 40 psi, fiber id 43 mils. 3" -316LSS inlet and outlet manifold. Three way fush and drain valves for each filter on manifold. Flush and drain lines tie to common header. |
|
|
| 96397 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 480 | 480 sq ft ultra filtration system. Mfd by US Filter/Alcoa. Type of filters - Membralox Ceramic Membranes (99.9% alpha alumina construction). Feed flow rate = 140 gpm; feed pressure = 120-180 pisg, loop flow rate = 1000 gpm, permeate pressure = 8-20 psig. Operating temp = 500 deg C. Membrane limitations = 1210 deg C, 300 psig, full range pH. Steam = 150 lbs/min, max per system = 125 psig saturated. Chilled water = 60 gpm (35% ethylene glycol). Calculated for (2) systems = 25 psig = 6 deg C. Instrument air = 100 psig. Module housing = 12P 19-60 (each module contains (12) membranes w/each containing (19) channels 60mm in dia). Fully automated control center. (2) 15 HP Triclover feed pumps; (2) 50 HP Goulds loop pumps (#94019-20); (2) 20 HP Goulds back pulse pumps. The (2) UF plants consists of (6) modules (2 parrallel sets of 3 modules each). Each module consists of (12) ceramic elements containing (19) parallel channels each, drilled lengthwise thru the elements. The inside of each channel is coated w/ceramic membrane serving as the separation media. An effluent containing approx 1% dye is pumped into one of two UF feed tanks. The effluent is pumped at approx 100 psig thru one of the UF plants. Water in the feed solution passes thru the ceramic membrane (permeate) and into the RO feed tank. The dye in the feed solution does not pass thru the membranes (concentrate) and is recycled back to the UF feed tank. High volume pump continuously recirculates part of the concentrate stream along w/the feed stream thru the modules to maintain a high velocity thru the modules. Steam heat exchangers are used to pre-heat the feed and chilled water coolers are used to removed heat developed thru circulation. During the filtration process the membranes will plug w/dye particles and permeate flow will decrease. Permeate stored in surge (backflushing) tank is pressurized and periodically pumped backwards for an instant thru the membranes (back pulsed) to wash the dye from the membranes. When the permeate rate slows due to plugging membranes or majot color change is made, the system is shutdown and cleaned chemically. Cleaning solution is circulated thru the modules followed by a fast back flush until the permeate rate improves. Pumps and valving are provided to completely remove dye from the entire system for color changes. The UF plant operations are controlled by Modicon programmable controller. The system will operate in semi-automatic mode. The operator will initiate sequence of operations and will be prompted by flashing status indicator when the sequence is complete and requires Safety alarms are built into the additional operator intervention programmed system. Feed tank agit cannot be operated if the tank level is below 3800 lbs. As the level decreases during operation, the agit will shut off at this level. High level of 24,000 lbs and low level of 800 lbs will activate an alarm. Permeate maybe directed to the reclaimed water tanks or to the switch station in addition to the RO feed tank by manual valves. The (2) UF feed tanks and UF plants are totally independent so that (2) dyes cab be processed simultaneously. |
|
|
| 96402 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | | Membrolox-Alcoa 316LSS sanitary, lab size, ultra filtration skid. SN MA10710E15042, Type 1PL9406VV85-S. Single cartridge measures 2" dia x 36" long. Has 500-A pore size and Viton gaskets. Components of skid include: (1) 10 gal 316SS feed tank w/(12) turns 1/4" copper coil; (1) Tri-Clover, 1 1/2 x 1 1/2, SS rotary pump, SN 20787, Mdl #PRED25-1-1/2M-TC1-4-4L-S, direct driven by 5 HP, 3/60/230/460 volt, 1725 rpm motor thru 4:1 ratio gearbox. Unit mtd on SS skid w/control box, Solenoid's flow meters and valves. |
|
|
| 103368 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | | Reverse osmosis system. Mfd by Millipore/Continental Water Systems. W/(9) 4" x 126" filters. Skid mtd. Also, w/(2) 250 gal polyprop tanks and (2) 20 HP, 3500 rpm CS centrifugal pumps. Complete with all controls, gauges and switches. Membrane #2941136, CD40401. Mtd on skid. |
|
|
| 107677 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 150 | 150 square feet Ronningen Petter, 304SS/brass ultra filtration unit. Model #B73-205-MX-AUTO, Serial #111338. Has (5) 4" diameter x 40" long brass cartridges. 4" diameter 304SS manifold. Has pneumatic discharge valve with solenoid. |
|
|
| 107692 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 150 | 150 square feet Ronningen Petter 304SS/brass ultra filtration unit. Model #B73-205-MX-AUTO, Serial #111338. Has (5) 4" diameter x 40" long brass cartridges. 4" diameter 304SS manifold. Has pneumatic discharge valve with solenoid. |
|
|
| 205892 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 1180 | 1180 Sq ft, 70 gpm, Koch RomiPure reverse osmosis water filtration sytem with accessories. Unit has (12) plastic membrane tubes, Type CTG, 5" diameter x 43" long, HF 132 -20-PM10, designed for ultrafiltration. Each membrane is rated 132 Sq Ft, 3.7 to 7.8 gpm. Skid mounted in stainless steel frame with controls. Unit has a combination of Stainless steel and PVC piping for corrosion resistance and ease of cleaning. Designed for 2" feed, complete with automatic control valves for fast flush. On board control panel features Flo rates and controls for flush cycles. |
|
|
| 205893 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 1180 | 1180 Sq ft, 70 gpm, Koch RomiPure reverse osmosis water filtration sytem with accessories. Unit has (9) plastic membrane tubes, Type CTG, 5" diameter x 43" long, HF 132 -20-PM10, designed for ultrafiltration. Each membrane is rated 132 Sq Ft, 3.7 to 7.8 gpm. Skid mounted with controls. |
|
|
| 213577 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | 100 | 225 gpm, CS, reverse osmosis skid manufactured by Membrane systems. With six Code line chambers, Model 413. Rated for 600psi at 20 degrees F to 120 degrees F. 4" diameter x 130" long. Overall skid dimensions 44" deep x 65" high x 140" long. 1.5" inlet line, rated for 40-70 degrees F inlet at 60 psi max. |
|
|
| 705864 | FILTER | REVERSE OSMOSIS AND ULTRA FILTRATION | | DDS Filtration Reverse osmosis system, type 30-19-3-HR95PP-PSO-NS-3.847.818, serial numbers # 2790 to # 2836-30-034-88,
System consists of:
6 x s/steel skids, 4 skids with 8-towers of plates and 2 skids with 7-towers, in total 46 towers, each tower with (186) 300mm diameter plastic plates, in total 8,556 plates, 316 s/steel end plates.
5 x 316 s/steel CIP systems, with (1) 65 ltr open top tank with cover, (1) Centrifugal pump, manufactured by Hilge, type Hygenia-bloc.1/3, 2900 rpm, driven by 2.2 kw, 3/50/220/380 volt, 2850 rpm motor, various valves, flow level glasses and filters, all mounted on s/steel frame.
5 x s/steel frames each with (1) Centrifugal pump, manufactured by Pasilac flow, type HI-220N-120, driven by 2.2 kw, 3/50/220/240/380/420 volt, 2870 rpm motor, (1) M.O.c-o-c flow dispersers, manufactured by Morinaga engineering ltd, control panel.
2 x underflow/overflow system, with (9-centrifugal pumps, manufactured by Pedrollo, type CP190, driven by 2 hp, 3/50/220/380- volt, 2800 rpm motor, numerous pressure gauges and flow level glasses, system mounted on (2) c/steel skids.
|
|
|
|
|
IPP Sales Contacts
|
 |
|
Keith West Global Sales KeithW@ippe.com +1 609 838 5931 | Amanda Vagell Global Sales AmandaV@ippe.com +1 609 838 5929 | Patti Buchman Global Sales PattiB@ippe.com +1 609 838 5928 | Ray Wagner Global Sales RayW@ippe.com +1 609 838 6043 | Regina Zarmer Europe Sales & Acquisitions ReginaZ@ippe.com +49-306-594-2445 Office +49-172-313-8439 Mobile +49-30-6594-2448 Fax | Jo Petrie, Sales Engineer UK, Scandinavia, Spain, & So.Africa jop@ippe.com +44 (0)1642 367 910 Office +44 (0)1642 367 913 Direct +44 (0)7770 748884 Mobile +44 (0)1642 367 920 Fax | Bohumil Cuta, E. Europe Sales & Acquisitions BohumilC@ippe.com +42-054-821-6680 Office +42-060-273-7517 Mobile +420-5-481-22240 Fax | Elisa Lucumi Central & So. America Sales ElisaL@ippe.com +1 609 838 5927
|
|
|
|
|
|
|
|