Chillers
|
 |
|
|
|
207432
125 Ton , Zero Degree Glycol chiller, Manufactured by FES, model # 19ME. Serial # 94623042. Chiller use's 1250 lbs. of R-22 refrigerent. Skid mounted with FES digital micro control panel. Compressor is by FES and exchangers are by FES, and Thermo Power-York. National Board # 9177, MAWP is 300 psi at 400 degrees F, MDMT is -20 at 300 degrees F. Compresssor driven by a 300 hp, 4160 volt, 3575 rpm motor.Glycol Flow= 500 GPM, colling water flow= 500 gpm, Inlet temp.= 10-15 degrees F. Outlet temp. is delta 10 Degrees F.
Read More...
|
| |
|
|
|
|
|
|
|
|
Used Generators – Power Generation Generators are designed to transfer energy from either burning fuels or capture of waste heat into electrical power. Generators fall into four major categories classified by the fuel that drives the generator.
There are Diesel Generators, Electric Generators, Steam Turbine Generators, and Gas Generators. Generator Sets are defined as the boiler or engine that burns the fuel with the electrical generator. These sets include the “prime mover” or engine, the generator, reduction gear, and exciter. Many of the generator sets powered by internal combustion engines (gas turbine, diesel, etc) the set usually included all of the components to produce electricity on one skid. Power plants are complete plants for the production of electricity. Power plants usually contain steam boilers, generator sets, transformers, and all the auxiliary equipment required to make electricity and may also produce steam for process use. Some common terms used for steam turbine generators include: - Prime Mover – the engine or turbine that moves the generator
- Condensing – a steam turbine that exhausts directly into a condenser at below atmospheric pressure
- Back Pressure – a steam turbine that exhausts into a process steam header at positive pressure – also called non-condensing or counter pressure.
- Extraction – steam bled off of a steam turbine before the exhaust. This steam is used for process application or for steam cycle efficiency. Can be “controlled” or “uncontrolled”. Also called bleed.
- Controlled – In extraction, this indicates that the turbine includes valves and regulators to control the pressure of the extraction flow over the rated flow range.
- Load Gear – this is the reduction gear between the prime mover and generator
|
|
Enter a product number or part of its description below and click SEARCH
Finally, you may filter the results based on capacity below
| 7 Items Returned | Go To Page: | 1 |
|
| | | Stock Number | Product | Sub Group | Capacity | Description |
|
|
| 41679 | GENERATOR | GAS | 2000 | 2,000 KW Turbo Systemns Int (now Rolls Royce/US Turbines), TG-20AT gas turbine generator set/complete plant w/9673 total operating hrs. Unit consists of twin Kawasaki M1T-01 turbine engines, designed for natural gas or light distillate fuel driving Kato generator thru Kawasaki reduction gear (8000/1800 rpm). Generator is rated 2500 KVA, .8 PF, 3 phase, WYE, 60 Hz (convertible to other frequencies), 4160 volt, 346 amp, 60 deg C temp rise. W/brushless exciter. Air cooled. System includes a Nebraska 50000 lbs/hr, 350 psi waste heat boiler, lube oil system, auxiliary transformer and full control system. |
|
|
| 212617 | GENERATOR | GAS | 10200 | 10200 kW, 4160 volt, CS, electric four pole synchronous AC brushless generator. Manufactured by Ideal. rated for 0.85 power factor output. Horizontal design, two bearing style, with single shaft extension. Windings intended to be WYE with full six leads, brought out, and equipped with damper windings to facilitate parallel operation with other generators. Bearings are sleeve type and eletrically insulated and forced oil is fed from an outside source. Bearings are also equipped with dial thermometers, return sight flow glass', and RTD protection. The bearings are also equipped with vibration probes in an X-Y orientation. Space heaters are also included and operate at 2400 watts, 120 vac, 60 hz. Available with lanfill gas boiler and steam turbine - see IPP stock number 210983 for complete system. |
|
|
| 216003 | GENERATOR | GAS | 180 | 180 kW, Emergency Generator, Natural Gas, 180kW Output, 60hz, 480vac, 3-Phase, Manufactured by Kohler. Serial # 388354, Model # 180HZD. With Block Heater, Battery Charger, Transfer Switch, Automatic Microprocessor Controlled, Nema 3 Enclosure, Outdoor Weather Housing, Residential Exhaust Silencer, 3-20 Second Time Delay Normal To Emergency, 4-Position (Test, With Load, Auto, Off, Engine Start), Pilot Lights For Normal Or Emergency Source, Engine by Detroit Diesel; S50G, 4-Cycle, Turbocharged, 1800rpm, Air cooled. Power factor 0.8 |
|
|
| 216312 | GENERATOR | GAS | 800 | 800 KW Caterpillar Natural Gas Generator Set Number 20502. Cat Engine Model G3516 SITA SN 3RC00095, 1085HP, built 1986. Operating speed 1200RPMs. Generator Model Number SR-4B, Serial Number 5YA01186, 800KW, 3 phase, 4 wire, 480V/1200A. Exciter 27V/80A, max temperature rise 115°C by resistance. Paired with a vertical heat exchanger 5’3”diax12’H |
|
|
| 216313 | GENERATOR | GAS | 800 | 800 KW Caterpillar Natural Gas Generator Set Number 20502. Cat Engine Model G3516 SITA SN 3RC00088, 1085HP, built 1986. Operating speed 1200RPMs. Generator Model Number SR-4, Serial Number 5YA00657, 800KW, 3 phase, 4 wire, 480V/1200A. Exciter 27V/80A, max temperature rise 115°C by resistance.
Paired with a vertical heat exchanger 5’3”diax12’H |
|
|
| 216314 | GENERATOR | GAS | 800 | 800 KW Caterpillar Natural Gas Generator Set Number 20502. Cat Engine Model G3516 SITA SN 3RC00096, 1085HP, built 1986. Operating speed 1200RPMs. Generator Model Number SR-4B, Serial Number 5YA00648, 800KW, 3 phase, 4 wire, 480V/1200A. Exciter 27V/80A, max temperature rise 115°C by resistance.
Paired with a vertical heat exchanger 5’3”diax12’H |
|
|
| 216315 | GENERATOR | GAS | 800 | 800 KW Caterpillar Natural Gas Generator Set Number 20502. Cat Engine Model G3516 SITA SN 3RC0089, 1085HP, built 1986. Operating speed 1200RPMs. Generator Model Number SR-4B, Serial Number 5YA80659, 800KW, 3 phase, 4 wire, 480V/1200A. Exciter 27V/80A, max temperature rise 115°C by resistance.
Paired with a vertical heat exchanger 5’3”diax12’H |
|
|
|
|
IPP Sales Contacts
|
 |
|
Keith West Global Sales KeithW@ippe.com +1 609 838 5931 | Amanda Vagell Global Sales AmandaV@ippe.com +1 609 838 5929 | Patti Buchman Global Sales PattiB@ippe.com +1 609 838 5928 | Ray Wagner Global Sales RayW@ippe.com +1 609 838 6043 | Regina Zarmer Europe Sales & Acquisitions ReginaZ@ippe.com +49-306-594-2445 Office +49-172-313-8439 Mobile +49-30-6594-2448 Fax | Jo Petrie, Sales Engineer UK, Scandinavia, Spain, & So.Africa jop@ippe.com +44 (0)1642 367 910 Office +44 (0)1642 367 913 Direct +44 (0)7770 748884 Mobile +44 (0)1642 367 920 Fax | Bohumil Cuta, E. Europe Sales & Acquisitions BohumilC@ippe.com +42-054-821-6680 Office +42-060-273-7517 Mobile +420-5-481-22240 Fax | Elisa Lucumi Central & So. America Sales ElisaL@ippe.com +1 609 838 5927
|
|
|
|
|
|
|
|