Need Help? or Have something for sale? USE THIS FORM:
|
|
|
|
|
|
|
|
Chillers
|
 |
|
|
|
203635
300 ton chiller designed to cool 40% Ethylene Glycol from 32 degrees F to 14 degrees F. Low temperature chiller skid manufactured by Frick (York International.) Frick # 292388. Designed to use R-22. This a complete skid mounted chiller including condenser, evaporate, and two (2) Frick RWBII-100E rotary screw compressors, designed for 350 psig high side, 300 psig low side, and each rated 298 BHP. Compressor A is a Model TDSH193S1746C, Ref. NH3/R22, Rated for max. speed of 4500 rpm. Max. Design pressure 362 psi. Compressor B is RWB II 100/100, serial # 30580MEMPTHAR2, ref. R22, Maximum speed is 3600 rpm. Max design pressure is 300 psi. Drivers are Reliance XE Premium Efficiency, 350 HP, 3570 rpm. ID # 1MAE73017. Rated for 3 ph, 60 Hz, 460 volts. Frame type 449TS. Comp. "A" 37490 Hours, Comp. "B" has 38193 hours. Evaporator is by Frick, NB # 109666, shell rated for 300 psi at 200 degrees F, Tubes not code. Built in 1993., Condenser is manufactured by Refrigeration Valves and systems, NB # 5428, Shell rated for 150 psi at 200 degrees F, tubes rated for 150 psi at 200 degrees F, Serial # 92945, Built 1993. Twin oil coolers are Frick NB # 109367, shell rated for 300 psi at 200 degrees F, tubes rated for 300 psi at 200 degrees F. Built in 1993. Complete skid mounted system with all piping and accessories. Controls are electronic, RWB II Plus, one for each compressor. Mounted in a stainless steel enclosure. Spare compressors are available.
Read More...
|
| |
|
|
|
|
|
|
|
|
Used Generators – Power Generation Generators are designed to transfer energy from either burning fuels or capture of waste heat into electrical power. Generators fall into four major categories classified by the fuel that drives the generator.
There are Diesel Generators, Electric Generators, Steam Turbine Generators, and Gas Generators. Generator Sets are defined as the boiler or engine that burns the fuel with the electrical generator. These sets include the “prime mover” or engine, the generator, reduction gear, and exciter. Many of the generator sets powered by internal combustion engines (gas turbine, diesel, etc) the set usually included all of the components to produce electricity on one skid. Power plants are complete plants for the production of electricity. Power plants usually contain steam boilers, generator sets, transformers, and all the auxiliary equipment required to make electricity and may also produce steam for process use. Some common terms used for steam turbine generators include: - Prime Mover – the engine or turbine that moves the generator
- Condensing – a steam turbine that exhausts directly into a condenser at below atmospheric pressure
- Back Pressure – a steam turbine that exhausts into a process steam header at positive pressure – also called non-condensing or counter pressure.
- Extraction – steam bled off of a steam turbine before the exhaust. This steam is used for process application or for steam cycle efficiency. Can be “controlled” or “uncontrolled”. Also called bleed.
- Controlled – In extraction, this indicates that the turbine includes valves and regulators to control the pressure of the extraction flow over the rated flow range.
- Load Gear – this is the reduction gear between the prime mover and generator
|
|
Enter a product number or part of its description below and click SEARCH
Finally, you may filter the results based on capacity below
| 7 Items Returned | Go To Page: | 1 |
|
| | | Stock Number | Product | Sub Group | Capacity | Description |
|
|
| 207925 | GENERATOR | STEAM TURBINE | 1007 | 1007 KW, 60 Hz, Elliott steam turbine generator set with Elliott turbines, Model BYRH-UG, Serial number B1002145-C 1, Single stage back pressure style units. Engine, gearbox and generator are mounted in a common skid. The Elliott gearbox reduces the turbine speed of 5750 RPM to a final speed of 1800 RPM to drive a conventional 4-pole, 2-bearing alternator rated 1000kW/1176kVA with 0.85 PF, 163 Amps and wound for 2400/4160V/3/60 Hz service.
Rated Power - 1350HP/1007kW; Rated Turbine Speed - 5750 RPM; Rated Inlet Steam Pressure - Gauge - 599 PSI; Rated Steam Temperature - 750 Deg F; Rated Exhaust Pressure - 155 PSI.
Gear Drive is a model # C4 R4, Serial # B102145C-G1, Rated power 1350, Service factor 1.66, High speed shaft;5750, Low speed shaft;1815 , Tag # 802654 C4 2624.
Alternater is built by BBC (Brown Boveri) Serial # C36-A076-102, Drive end bearing 6322/C3, opposite drive end bearing 6320/C3. Time rated continuous; Frame # 717, enclosure is drip proof; rated ambient temp. 40 degrees C.
With twin Amtek oil coolers and 1.5 hp oil pump.
The package includes generator control and synch panels with scope, no boilers with units. |
|
|
| 207926 | GENERATOR | STEAM TURBINE | 1007 | 1007 KW, 60 Hz, Elliott steam turbine generator set with Elliott turbines, Model BYRH-UG, Serial number B1002145-C 2, Single stage back pressure style units. Engine, gearbox and generator are mounted in a common skid. The Elliott gearbox reduces the turbine speed of 5750 RPM to a final speed of 1800 RPM to drive a conventional 4-pole, 2-bearing alternator rated 1000kW/1176kVA with 0.85 PF, 163 Amps and wound for 2400/4160V/3/60 Hz service.
Rated Power - 1350HP/1007kW; Rated Turbine Speed - 5750 RPM; Rated Inlet Steam Pressure - Gauge - 599 PSI; Rated Steam Temperature - 750 Deg F; Rated Exhaust Pressure - 155 PSI.
Gear Drive is a model # C4 R4, Serial # B102145C-G2, Rated power 1350, Service factor 1.66, High speed shaft;5750, Low speed shaft;1815 , Tag # 802654 C4 2625.
Alternater is built by BBC (Brown Boveri) Serial # C36-A076-101, Drive end bearing 6322/C3, opposite drive end bearing 6320/C3. Time rated continuous; Frame # 717, enclosure is drip proof; rated ambient temp. 40 degrees C.
With twin Amtek oil coolers and 1.5 hp oil pump. |
|
|
| 210492 | GENERATOR | STEAM TURBINE | 283 | 283KW/404 HP, CS, Skid mounted turbine generator package. This set is designed to recover the work available in high pressure steam that would normally be lost when the steam passes through a pressure reducing valve. The system consists of a backpressure steam turbine driving a synchronous generator mounted on a skid. The control system automatically controls the flow of the steam through the turbine, thereby controlling the pressure in the low pressure header. The major components are as follows: Turbine by Coppus Engineering, Model # RLHA-19, Serial # 94H9489. This is a single-stage, impulse type turbine. Capable of delivering 404 HP at 3600 rpm, designed for 23,075 lbs. /hr, of dry saturated steam at 210 psi. Generator is manufactured by Kato, and is high efficiency design, synchronous, and brushless, and revolving field style. Type: 26182, Model # A261820000, Serial # 11302. Operating at 3600 rpm, delivering 480 volt, 3 ph, 60 Hz, 283 kW of output. Alternator kW continuous, 285, 60 Hz, 277/480v, 428.5 amps. Exciter Arm "C" # 3007-10, Exciter Field "C" # 18058-10. The control panel and circuit breaker handle synchronization, metering, protection and other functions. |
|
|
| 600172 | GENERATOR | STEAM TURBINE | 5 | 5,250 KW, 50 Cycle, Escher Wyss steam turbine generator set, with extraction. Turbine: Escher Wyss, Type REA 1600. Designed for 5,240 KW, Rpm: 6,600, Inlet Pressure: 36 Kp/SqCm @ 410 degrees C, Extraction 1 - non controlled 2800 Kg/H, Extraction 2 - controlled 27,000 Kg/H, pressure 11-14 Kp/SqCm. Generator:Type 14S250, 6600 KVA , COS Phi 0.8, Voltage: 11 KV, 50 Hz. SEE PLANT INVENTORY FOR MORE INFO.
|
|
|
| 704429 | GENERATOR | STEAM TURBINE | 3000 | 3000 KW, 3750 KVA, steam turbine generator.This consists of (1) steam turbine mfd by WH Allen and Sons, SN T4/7284(7), 4500 HP, speed 10250 rpm, gearbox speed 1500 rpm. Inlet pressure 635 psi @ 670 deg F, exhaust pressure 100 psi. (1) generator mfd by Bruce Peebles, SN 94359, 1500 rpm, 11000 volt, 50 Hz, Type 'B' insulation. (1) exciter generator, mfd by Westinghouse, 17.6 KW, 18.5 KVA, 1500 rpm, 3 phase, 50 Hz, 30.5 volt. (1) oil cooler, (1) oil filter, (1) gland condenser, (1) combined stop & emergency valve, (1) control panel |
|
|
| 706415 | GENERATOR | STEAM TURBINE | 1495 | 1495 kW KKK Ltd back pressure turbine generator, 1530 kW max, serial # 4555.002, model CFR 5G5, integrally geared high efficiency single stage design, 29 tonne/hr (max) live steam @ 23 kg/cm2g and 340 deg C, exhausting back pressure 5.6 to 8.5 kg/cm2g @ 226 to 257 deg C, 282 to 1495 kW output, assumed generator efficiency 89.6 to 95.3%, mech output 315 to 1569 kW, turbine speed 10740 rpm, coupling speed 1500 rpm |
|
|
| 800001 | GENERATOR | STEAM TURBINE | 2150 | 2150 kw, gas turbine set, mfd by Kawasaki (Deutz MWM) serial # KA 2334, type M1A-23, duel fuel, exhaust gas temp 578 deg C, exhaust gas mass flow 9,26 kg/sec, fuel consumption 8092 kw, inlet air temp 15 deg C, inlet air flow 9.3 kg/sec (7.2 Nm3/sec), 2-stage radial compressor, 4-stage axial turbine, rotor speed 21,964 rpm @ 50 hz, output shaft speed 1,500 rpm @ 50 hz.
turbine driving B3 design synchronous generator, brushless type, nominal rating temp 40 deg C, self regulating with damper cage, pilot exciter and standstill heating
system also includes exhaust diffuser, lube oil system, air intake filter, control panels. |
|
|
|
|
IPP Sales Contacts
|
 |
|
Keith West Global Sales KeithW@ippe.com +1 609 838 5931 | Amanda Vagell Global Sales AmandaV@ippe.com +1 609 838 5929 | Patti Buchman Global Sales PattiB@ippe.com +1 609 838 5928 | Ray Wagner Global Sales RayW@ippe.com +1 609 838 6043 | Regina Zarmer Europe Sales & Acquisitions ReginaZ@ippe.com +49-306-594-2445 Office +49-172-313-8439 Mobile +49-30-6594-2448 Fax | Jo Petrie, Sales Engineer UK, Scandinavia, Spain, & So.Africa jop@ippe.com +44 (0)1642 367 910 Office +44 (0)1642 367 913 Direct +44 (0)7770 748884 Mobile +44 (0)1642 367 920 Fax | Bohumil Cuta, E. Europe Sales & Acquisitions BohumilC@ippe.com +42-054-821-6680 Office +42-060-273-7517 Mobile +420-5-481-22240 Fax | Elisa Lucumi Central & So. America Sales ElisaL@ippe.com +1 609 838 5927
|
|
|
|
|
|
|
|