Need Help? or Have something for sale? USE THIS FORM:
|
|
|
|
|
|
|
|
Featured Equipment
|
 |
|
|
|
210983
10 megawatt gas fired combined heat and power cogeneration facility including boiler,steam turbine, generator and condenser. Burns Natural Gas, Methane, Landfill Gas, Biogas. View video overview at www.ippe.com/PlantSearch/PlantDetail/tabid/118/pid/210983/Default.aspx. Boiler manufactured by Deltek, recently re-tubed. Rated for 125,000 lbs steam per hour at 725 psi. Heating surface square footage is 16,189. Burner is capable of handling Natural Gas or Methane as the fuel. Steam Turbine rated for 101,000 lbs./hr. at 600 psi for 750 degrees F., and includes an electronic Woodward governor. Reduction gear by Tacke, rated for 6,200 rpm in and 1,800 rpm out. Generator is manufactured by Ideal Electric Company and is rated at 10MW, 11,647 kVA, 4160 volt at 1800 rpm & 60 Hz. With brushless exciter. Condensing is handled by a 7,809 sq. ft. Grahm exchanger, featuring admiralty brass tubes. Condenser is rated for 88,100 lbs./hr. exhaust, 86 mm BTU/HR. duty and requires 6,880 gpm of cooling water. Complete with all support equipment, including pumps, water systems, blowers,etc. Complete control room available with operational control panels featuring controls by Panalarm, Foxboro, Bently Nevada, and Bassel.Starters and switch gear by Siemens, is also available.
Read More...
|
| |
|
|
|
|
|
|
|
|
Used Heat Exchangers & Used CondensersUsed Stainless Steel Heat Exchangers
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet.
There are several different types of heat exchangers. These include: - Shell and Tube - Also called a condensers and calandrias depending on the service, this type of heat exchanger has external cylinder called a shell with internal tubes that run the length of the shell. There are tube sheets on each end of the tubes sealing the shell around the tubes. There are covers on each end called heads and these can come in several configurations. The shell side has a pressure and temperature rating and the tube side has a pressure and temperature rating. They can be vertical or horizontal. Basic principal of operation is that one fluid flows through the tube and the other fluid flows around the tubes. The fluid inside the tubes can flow in a single pass or multiple passes using baffles in the heads.
- Graphite Exchangers - Graphite block exchangers are typically made from a solid block of graphite with parallel holes drilled at right angles. The blocks can be cylindrical or cube shaped. The blocks are typically stacked with gaskets in-between to product more square foot surface area. The blocks are inserted in carbon steel housing. Graphite shell and tube exchangers have graphite tubes and heads with Carbon Steel shells.
- Plate Heat Exchangers - Plate exchangers consist of a series of alloy plates held together by a frame. The frame can be opened to add or repair the plates. One liquid flows through alternate plates and the other liquid flow the opposite direction through the opposite plates.
- Spiral Heat Exchangers - Spiral exchanger are made from a pair of plates rolled to provide two relatively long rectangular passages for fluid in counter current flow. The spiral design is compact.
- Fin Fan / Air Fin Exchangers - This type of exchanger has radial fins on the outside of the tubes to extend the heat transfer surface area. Tubes are mounted in horizontal banks, and multiple fans blow air across the outside of the tubes for cooling the process fluid inside the tubes.
- Compoblock - This new type of heat exchanger is like a plate exchanger except the plates are welded together instead of gasketed, and the plates are mounted in a cube shaped shell like a graphite block exchanger. This type offers compact design, ability to use high alloys, and closed environment to prevent leaks.
|
|
IPPE Used Process Equipment Search Enter a product number or part of its description below and click SEARCH
Now choose a product sub group (if any are present below)
|
| | | Stock Number | Product | Sub Group | Capacity | Description |
|
|
| 3467 | HEAT EXCHANGER | COPPER BRASS | 400 | Approx 400 sq ft tube and shell heat exchanger. 14" dia x 16' long brass tubes. Floating head, CS heads. Shell connections 2-3", 2- 1 1/4", head connections 2-2", 1-1", 1-1 1/2". 8' overall length. |
|
|
| 12451 | HEAT EXCHANGER | GRAPHITE | 1933 | ****1,933 sq ft graphite vert tube, CS shell heat exchanger. Mfd by Carborendum, Falls Ind, SN 5514. Rated 50 psi @ 340 deg F tube side, 75 psi shell side @ 340 deg F. (608) 2" OD x 6' long graphite tubes. Heads are teflon coated. NB# shell only MK1-E101. CS shell 5'6" dia x 11'8" long. Openings: 2-10" shell side; 1-24", 1-12" tube side. Single pass. (4) mounting lugs. |
|
|
| 13267 | HEAT EXCHANGER | SHELL TUBE - STAINLESS | 1700 | ****NEW UNUSED 1,700 sq ft vert SS tube, CS shell heat exchanger. Mfd by Foster Wheeler, Unit #X-226, SN: -1,44-2786-15. Rated 50 psi and full vac @ 300 deg F shell side, 725 psi @ 300 deg F tube side. 304SS tubes 6' long, SS tubesheet. (2) CS CS flat heads. CS shell 3'8" dia x 15' long. Outlets: shell 2-2 1/2"; heads 2-2 1/2". |
|
|
| 19500 | HEAT EXCHANGER | PLATE AND FRAME | 2000 | Approx 2,000 sq ft 316SS plate heat exchanger. Mfd by American Heat Reclaiming, SN 10910, NB #8395. Unit has (275) plates, 23" wide x 4'6" long. Designed for 125 psi @ 250 deg F. Unit has 2-8" inlets and 2-8" outlets. |
|
|
| 19551 | HEAT EXCHANGER | SHELL TUBE - STAINLESS | 30 | Approx 30 sq ft all 316SS horiz U-tube and shell heat exchanger. Approx 14' long around bend 316SS U-tubes, 316SS tubesheet. 316SS heads. 316SS shell 4" dia x 93" long. |
|
|
| 20874 | HEAT EXCHANGER | SHELL TUBE - CARBON STEEL | 1552 | 1,552 sq ft horiz CRMO U-tube, CS shell heat exchanger. Mfd by Alco, SN 55888, National Board rated. Type AEU. Rated 450 psi @ 850 deg F tube side, 535 psi @ 600 deg F shell side. (276) 1" x 117" long CRMO tubes, CS tubesheet. Removable tube bundle. (2) CS heads (1-dished, 1-flat). CS shell 3' dia x 17' long. Openings: shell 2-12"; heads 2-12". |
|
|
| 22137 | HEAT EXCHANGER | GRAPHITE | 91 | 91 sq ft cylindrical graphite tube, CS shell heat exchanger. Mfd by Union Carbide, Size 10-108, CPD #6A35973. Shell and tubes rated 75 psi @ 338 deg F. (31) 7/8" ID x 9' long tubes. CS shell 10" dia x 11' overall length. Openings: one head 1-3"; other head 1-6"; shell 2-3". |
|
|
| 23163 | HEAT EXCHANGER | GRAPHITE | 99 | 99.5 sq ft Union Carbide graphite tube side, CS shell heat exchanger. Unit has (19) 7/8" ID, 1 1/4" OD x 16' long tubes. Shell 8" dia x 220" overall length. |
|
|
| 25223 | HEAT EXCHANGER | GLASS LINED | 135 | 135 sq ft glass tube, CS shell heat exchanger. Mfd by Corning, Mdl MDH9/135. Tube side rated 75 psi @ 350 deg F, shell side rated 75 psi @ 350 deg F. (72) 3/4" OD x 13' long glass tubes. PTFE tubesheet. No heads. Single pass design. CS shell 9" dia x 13'5" overall length. |
|
|
| 26501 | HEAT EXCHANGER | GRAPHITE | 53 | 53 sq ft graphite cubic block heat exchanger. Mfd by Falls Ind. Single pass process side, two pass service side. Rated 100 psi @ 340 deg F process and service. Openings: 2-6" process, 2-2" service. Dimensions: 2' x 2' x 2'. |
|
|
| 27036 | HEAT EXCHANGER | GRAPHITE | 200 | 200 sq ft Kearney graphite block heat exchanger. SN 18532-200/100. Rated 50 psi @ 360 deg F process side, 75 psi @ 360 deg F service side. Single pass process side w/2-6" ID openings, 8 pass cooling side w/(4) 2 1/4" ID openings. |
|
|
| 27689 | HEAT EXCHANGER | SHELL TUBE - CARBON STEEL | 4680 | 4,680 sq ft all CS horiz U-tube and shell heat exchanger. Mfd by Southern Heat Exchanger, SN 85-053A, NB #4133, blt 1985, Type BHU, Size 49-168. Tube side rated 275 psi @ 350 deg F, shell side rated 275 psi/full vac @ 350 deg F. (1,490) 3/4" dia x 14 bwg x 16' long CS U-tubes. CS heads. 2 pass design tube side. CS shell 50" dia. Double split flow shell. Mtd on saddles. |
|
|
| 27756 | HEAT EXCHANGER | SHELL TUBE - CARBON STEEL | 1661 | 1,661 sq ft CS heat exchanger. 525 psi @ 170 deg F shell side, 700 psi @ -50 deg F tube side. (360) 3/4" x 16 gauge x 24' long CS tubes. 24" dia CS shell. CS heads. 2 pass shell and tube side. 2-8" shell side nozzles, 2-4" tube side nozzles. |
|
|
| 28086 | HEAT EXCHANGER | SPIRAL | 15 | 15 sq ft all 316SS spiral heat exchanger. Mfd by American Heat Reclaiming, Type 1H, SN 10655, NB #7803. Rated 65 psi @ 160 deg F hot side, inner pass is .25" x 6", 14'5" long; cold side outer pass is .25" x 6", 15'4" long. 1" inlets and outlets. |
|
|
| 29280 | HEAT EXCHANGER | AIR FIN | 685 | NEW UNUSED 685 sq ft Esex air cooled heat exchanger. SN 733038-A1, NB #353, Mdl 414A08F1210. Tube side rated 100 psi @ 450 deg F. (402) 1" OD x 6'6" long SB111 Admiralty welded tubes (arranged in 12 rows). CS tubesheet. 2 pass design. (2) CS manifolds. CS sheet metal housing w/20" dia air inlet and outlet. Openings: tube side 2-8". |
|
|
| 29282 | HEAT EXCHANGER | AIR FIN | 685 | NEW UNUSED 685 sq ft Esex air cooled heat exchanger. SN 733040-A1, NB #355, Mdl 402A08E126. Tube side rated 100 psi @ 450 deg F. (402) 1" OD x 6'6" long SB111 Admiralty welded tubes (arranged in 12 rows). CS tubesheet. 2 pass design. (2) CS manifolds. CS sheet metal housing w/20" dia air inlet and outlet. Openings: tube side 2-8". |
|
|
| 30640 | HEAT EXCHANGER | GRAPHITE | 140 | 140 sq ft graphite tube, CS shell heat exchanger. Mfd by Kearney, NB #1041, SN 9423, blt 1988. Tube side rated 75 psi @ 360 deg F, shell side rated 75 psi @ 360 deg F. (30) 1 1/4" OD x 14'4" long graphite tubes. Graphite tubesheet. Graphite heads. CS shell 10" dia. Openings: shell 2-4"; heads 2-2". |
|
|
| 33013 | HEAT EXCHANGER | GRAPHITE | 26 | Nominal 26.5 sq ft graphite tube, CS shell heat exchanger. (9) 7/8" ID x 9' tubes. Horiz design. 6" dia shell. Openings: shell side 1-2", 1-1 1/2"; tube side 2-2". (Not to be used for products mfd for human or animal consumption). |
|
|
| 34268 | HEAT EXCHANGER | SHELL TUBE - STAINLESS | 3957 | NEW UNUSED 3,957 sq ft vert 304LSS U-tube, CS shell and head heat exchanger. Mfd by Joseph Oat, Type CEU, SN 2306G, NB #1002. Tube side rated 150 psi @ 150 deg F, shell side rated 250 psig @ 150 deg F. (350) 3/4" dia x 18 bwg x 28' str side 304LSS U-tubes, 304SS tubesheet. CS channel head. Single pass shell. CS shell 31" dia 33' overall length. Shell 2-8" connections; tube 2-8" connections. |
|
|
| 34272 | HEAT EXCHANGER | SHELL TUBE - STAINLESS | 3957 | NEW UNUSED 3,957 sq ft vert 304LSS U-tube, CS shell and head heat exchanger. Mfd by Joseph Oat, Type CEU, SN 2306F, NB #1001. Tube side rated 150 psi @ 150 deg F, shell side rated 250 psig @ 150 deg F. (350) 3/4" dia x 18 bwg x 28' str side 304LSS U-tubes, 304SS tubesheet. CS channel head. Single pass shell. CS shell 31" dia x 33' overall length. Shell 2-8" connections; tube 2-8" connections. |
|
|
|
|
|
IPP Sales Contacts
|
 |
|
|
Keith West Global Sales Email Keith Direct: 1-609-838-5931 Office: 1-609-586-8004 |
Amanda Vagell Global Sales Email Amanda Direct: 1-609-838-5929 Office: 1-609-586-8004 |
Patti Buchman Global Sales Email Patti Direct: 1-609-838-5928 Office: 1-609-586-8004 |
Ray Wagner Global Sales Email Ray Direct: 1-609-838-6043 Office: 1-609-586-8004 |
|
Central Europe Sales & Acquisitions
Regina Zarmer Email Regina Office: 49-306-594-2445 Mobile: 49-172-313-8439 Fax: 49-30-6594-2448 |
UK, Scandinavia, Spain & South Africa Sales & Acquisitions
Office: 44 (0)1642-367-910 Fax: 44 (0)1642-367-920
Jo Petrie Email Jo Direct: 44 (0)1642-367-913 Mobile: 44 (0)7770-748-884
Nicola Douglas Email Nicola Mobile: 44 7940 981 681 |
Eastern Europe Sales & Acquisitions
Bohumil Cuta Email Bohumil Office: 42-054-821-6680 Mobile: 42-060-273-7517 Fax: 42-054-812-2240 |
Central & South America Sales
Elisa Lucumi Email Elisa Direct: 1-609-838-5927 Office: 1-609-586-8004
|
|
|
|
|
|
|
|