RegisterLogin
Need Help? or Have something for sale? Use this:






Submit  

     

  You are here:  Equipment Search   
Equipment Search

Enter a product number or part of its description below...
  Search View Quote Contents

OR

Now choose a product sub group (if any are present below)
9 Items ReturnedGo To Page: 1
  Stock NumberProductSub GroupCapacityDescription
Select
3055INCINERATOR  1.4MMApprox 835 cfm Trane Thermal fume incinerator. Mfd by Trane Thermal Co. System designed to incinerate combustible chemical fumes for air pollution compliance. Operated on DMA plant Emissions w/max content of 127 lb/hr Dimethyl ether, 9 lb/hr methanol and 27 lb/hr DMA dimethylaniline, incinerating "all organics in vent gases". Oil fired w/gas pilot. Unit skid mtd. Prepiped and prewired.
Select
17350INCINERATOR  18,500 cfm vert brick lined CS fume incinerator. Mfd by Air Preheater. Main oxidation chamber measures 5' wide x 32' long x 14' high. CS construction w/refractory lining. Dual fuel gas and #6 oil. W/controls and burner.
Select
22998INCINERATOR  3,000 scfm induced draft horiz vapor incinerator. Mfd by Hirt Combustion Engr, Mdl HIH-5M3000X, SN 8601270. W/automatic inlet damper. Unit designed to incinerate 3,000 scfm @ 1200 deg F using natural gas. Inlet fumes were 300 deg F. Induced draft fan operated @ 500 deg F w/13,312 cfm flow rate.
Select
34423INCINERATOR  21.0MM21.0MM BTUH Trane Thermal chlorinated hydrocarbon incinerator w/waste heat recovery. Designed for various chemical solvents entrapped w/water. Max flow of water for incineration 1550 lb/hr. Unit is rated @ 21MM BTUH system consists of Trane Thermal horiz incinerator 6'6" dia x 15' long. Refractory lined. CS shell. Primarily fired on steam atomized #6 fuel oil. Maintaining a min temp of 2400 deg F. Burner is Trane Thermal LV-24 vortex burner. Firing 140 gph max, gas pilot ignition. Auxillary equipment for burner includes: FM insurance approved piping train for #6 fuel oil and waste. Waste piping is 316SS. Main combustion air fan is CS Spencer turbine rated 5,000 scfm @ 24 osig, powered by UL label 60 HP, 3/60/460 volt motor. ABCO elevated drum fire tube waste heat boiler. Single pass, 5'10" dia x 30' long x 13' high. Producing 10,000 lbs/hr @ 200 psig saturated steam. Feed water rate 250 psig-7650 lb/hr @ 220 deg F. Scrubber system is packed column 3'6" dia x 18'. CS shell lined w/Pyroflex and 4 1/2" acid brick. Ceramic intalux saddle packing. Stack is 12" dia x 10' high FRP. Quench air fan requires 30 HP motor (motor is missing). CS Garden City, designed temp 700 deg F. Pumps for scrubber system are duplexed 316SS Durco 5 HP, 3490 rpm. Remote control panel controls and meters. Boiler inlet temp, waste solvent feed rate, steam produced, scrubber exit temp, recycle air temp, incinerator chamber temp, boiler water level, feed water rate to boiler, liquid level in scrubber.
Select
203160INCINERATOR 16191,619 ACFM, CS, Thermal Oxidizer system designed by Process Combustion with ABCO waste heat boiler, and Celicote scrubber system. ABCO waste heat boiler, Rated at 1750 Lbs/hr, NB# 3121, rated 250psi, 453 SqFt, built 1993, serial number 9301, model Waste Heat Firetube. With (49) 2.5" x 152" long tubes. Celicote final Scrubber, Model # SPT-24-84, Item # 16B, Rated for -6" WC to +12" WC, design temprature 180 degrees F, air flow capacity1,619 ACFM, material Dekrane 411.45. Preheat tube, Carbon Steel, 48" diameter by 196" long. Inlet 4" with a 11" outlet.
Select
207290INCINERATOR 040' Combustion chamber
Select
207291INCINERATOR 040' combustion chamber
Select
210004INCINERATOR 3853748450 m3/hr (max) CS, Ecopure Regenerative Thermal Oxidizer, type RTOC3-3040, efficient exhaust gas purification system, manufactured by Durr Systems Gmbh, serial # 9377, order # 406-301-5, minimum flow volume 10,450 m3/hr, max pressure drop 6000 pa, combustion chamber temperature (regulator) 820 deg C, burner capacity 2 x 850 kw (max). Overall system data: Overall length of system 23344mm x 8284mm wide x 7490mm high, chimney stack height 13025mm, (3) RTO regenerator sectors, volumetric exhaust air flow, minimum 10450 Nm3/hr, average 47750 Nm3/hr, max 48450 Nm3/hr, exhaust air inlet temperature 20 deg C (nominal), Oxygen content in exhaust air 18% (min), exhaust air pressure at inlet to RTO system -5 mbar, quantity of pollutants in exhaust air 71 kg/hr (average), pollutant concentration 1.5 g/Nm3, net calorific value of pollutants approx 11.93 kWh/kg, exhaust preheating by ceramic heat exchanger approx 780 deg C, combustion chamber temperature 820 deg C, cleaned gas outlet temperature approx 68 deg C, Thermal reactor data: Reactor column 10120mm x 3620mm, sector 3260mm x 3620mm, column height 2130mm, layer height of ceramic honeycomb blocks 1.8m, sub-construction height 3670mm, distance between sectors 200mm, Combustion Chamber: Dimensions 10140mm long x 3480mm wide x 1690mm high, (2) gas burners each 850 kw (nominal) capacity, pre-pressure of natural gas 167 mbar, net calorific value of natural gas 10 kWh/Nm3, Air system: Process, purge, fresh, exhaust and crude air temperature approx 20 deg C, cleaned gas approx 68 deg C, cleaned gas fan volumetric flow 54000Nm3/hr nominal, 73780 m3/hr @ 100 deg C, speed 1665 rpm, total pressure difference 7730 pa, motor 200 kw, combustion air fan volumetric flow 3720 m3/hr, total pressure difference 8700 pa, motor 7.5 kw, 2880 rpm, purge air fan volumetric flow 2640 m3/hr, total pressure difference 3500 pa, motor 3.1 kw, 2830 rpm, Electrical equipment: Operating voltage 3 x 415 V, 50 Hz, burner, general control and motor valve voltage 240 V, 50 Hz, control I/O level, signal lamp, valve and interlocking voltage 24 V DC,
Select
211411INCINERATOR 0UNUSED Process Combustion thermal oxidizer, Model NPO-1192-28. Single burner design. With control panel. Mounts vertical. With unused burners, valves, controls, & blower package.
  

Home | About IPP | Equipment Search | Plant Search | Contact Info. | Sell your assets | Downloads | Ayton Equipment
  Copyright 2002-2008 International Process Plants   Terms Of Use  Privacy Statement