RegisterLogin
Need Help? or
Have something for sale? USE THIS FORM:
First Name:  
Last Name:  
Email Address:  
Company Name:  
Telephone:  
Country:  
Question:  
 
     

Chillers Minimize
1 of 10
207381
165 Ton @ -32 degrees F, Dunham Bush horizontal screw refrigeration package. Water cooled design. R22 Refrigerant. Compressor Model 2515/5.40, Horizontal Rotary Screw, rated 3550 RPM, direct coupled to a Siemens 600 HP, 3/60/460 volt motor. Evaprator is a 2 pas, 24" diamter x 176" long, (288) 3/4" x 0.049 x 176" long trufin tube carbon steel tubes; Condensor is a 2 pass, 18" diameter, x 153" long, (228) 3/4" x 0.028" x 153" long tubes, trufin copper tubes. All skid mounted with lubeoil system, and digital control panel. With Westinghouse starter WYE-Delta Closed Transition, NEMA-1 encloser floor mount. Unit dimensions are 212" L x 8"W x 116" H, 24,500 lbs.
Read More...
 
  

 
Equipment Search
IPPE Inventory Record Detail
Stock Number111055
PGSYSTEMS
SG 
SSG 
Capacity 
Product DescriptionThe membrane cell electrolysis system is designed for manufacturing H3P02. Hypo Acid). Water, electricity and NaHYPO is fed into the cell system, 02 and H2 are removed separately, H3P02 are the product. The entire system was supplied in 1998. The capacity is 706 TPY with a down time of 15%. So it means a practical capacity of 600 TPY. It was supplied by Aqua Tech Cell. The electrodialysis is as follows: The treated salt solution is processed in the Aqualytics electrodialysis system. The process is made up of the following components: * The process area, where the process equipment and instrumentation are located. * The power supply, which supplies DC power the cell stack skid. * Cell stack skid which contains the membranes; The Aqualytics system requires deionized water feed (included). Deionized water is supplied from a unit that is fed cooled (<38 degrees C) steam condensate water from a sodium hypophosphite evaporator steam chest. The Aqualytics system requires a purified sodium hypophosphite solution feed. Sodium hypophosphite solution is passed through the CSK cation exchange system, where hardness ( Calcium or Magnesium) is removed to <1ppm total hardness. The aqualytics system employs the use of: * A bipolar membrane. * An Anion selective membrane. * A Cation selective membrane. The entire system consists of the following components: -150 gallon HOPE tank for 15% Hype Acid, Mfg. by Chem Tamer. -Acid pump, made of PP size 1 1/2 x 1 1/2, rated 45 GPM, driven by 1 HP 3160/460V 3600 RPM motor. -Acid filter, (north), Mfg by Trumpler- Clancy/ Filtrite, made of PPrated 20 GPM c~ 125 PSI, with 10 micron cartridge. -Acid filter (south), identical to the one above. -NaOH base tank, made of HDPE, Mfg by Chem- Tamer, 55 gallons. -Base pump, Mfg by Pertech mdl MDH 401 CV6, rated 45 GPM c~ 46 TDH, driven by 1 HP 3/60/460V 3600 RPM motor. -Base cooler, 22.6 Sq. Ft. plate heat exchanger, 316SS, Mfg. by Alfa Laval, rated 92500 BTU/Hr. -Base filter, (west), made of PP, Mfg. by Trumpler- Clancy/ filtrite, with 10 micron cartridge, rated 20 GPM (~ 125 PSI. -Base filter (east), same as above. -Salt tank, made of HOPE, 55 gallons, Mfg by Chem Tamer. -Salt pump, made of PP, rated 45 GPM c~ 46 TDH, Mfg by Pertech MDH 401 CV6, driven by I HP 31601460V 3600 RPM motor. -Salt Filter (south), made of PP, Mfg. by Trumpler- Clancy, rated 20 GPM C~ 125 PSI, with 10 micron cartridge. -Salt filter (north), same as above. -Salt cooler, 22.6 Sq. Ft. 316 SS plate heat exchanger, mfg by Alfa Laval, rated 92580 BTU/ Hr. -Cathode rinse tank, made of HOPE, 15 gallons, Mfg by Chem tamer. -Cathode rinse pump, made of PP, Mfg by Pertech, MDH400CCVY, rated 14 GPM (~ 23 TDH, driven by 112 HP, 3160/460V 3500 RPM motor. -Cathode rinse filter, made of PP, rated 20 GPM @ 125 PSI, Mfg. by TrumplerClancy, with 10 micron cartridge. -Anode rinse tank, made of HOPE, 30 gallon, Mfg by Chem-Tainer. -Anode rinse pump, made of PP, Mfg by Pertech, type MDH400CCVy, rated 14 GPM @ 23T0H, driven by 1/2 HP 31601460V, 3500 RPM motor. -Anode rinse filter, made of PP, Mfg by Trumpler- Clancy, rated 20 GPM @ 125 PSI, with 10 micron cartridge. -Caustic mix tank, made of HOPE, 10 gallons, Mfg by Chem Tamer. -Cell Stack power supply, 250V0C1 600 A. - Cell stack mfg. by Aqualytics with a cell monorail hoist.

  

IPP Sales Contacts Minimize
Keith West
Global Sales
KeithW@ippe.com
+1 609 838 5931
Amanda Vagell
Global Sales
AmandaV@ippe.com
+1 609 838 5929
Patti Buchman
Global Sales
PattiB@ippe.com
+1 609 838 5928
Ray Wagner
Global Sales
RayW@ippe.com
+1 609 838 6043
Regina Zarmer
Europe Sales & Acquisitions
ReginaZ@ippe.com
+49-306-594-2445 Office
+49-172-313-8439 Mobile
+49-30-6594-2448 Fax
Jo Petrie, Sales Engineer
UK, Scandinavia, Spain, & So.Africa
jop@ippe.com
+44 (0)1642 367 910 Office
+44 (0)1642 367 913 Direct
+44 (0)7770 748884 Mobile
+44 (0)1642 367 920 Fax
Bohumil Cuta,
E. Europe
Sales & Acquisitions
BohumilC@ippe.com
+42-054-821-6680 Office
+42-060-273-7517 Mobile
+420-5-481-22240 Fax
Elisa Lucumi
Central &
So. America Sales
ElisaL@ippe.com
+1 609 838 5927

     

Home | About Us | Equipment Search | Plant Search | Industrial Real Estate | Sell to IPP | News | Media | Contact Us
  Copyright 2002-2010 International Process Plants   Terms Of Use  Privacy Statement   
The European Petrochemical Association International Fertilizer Industry Association Institute of Scrap Recycling Industries, Inc. National Demolition Association Society of Chemical Manufacturers and Affiliates Turnaround Management Association Association Memberships
Bookmark and Share

Follow Us On Twitter View Our Channel on YouTube