 |
Register Login |
 |
|
 |
- Home
- About Us
- Equipment Search
- Plant Search
- Industrial Real Estate
- Bromborough, England
- Bloomsbury, New Jersey
- Coventry, Rhode Island
- Fitchburg, Massachusetts
- Florence, South Carolina
- Liverpool, England
- Lowell, North Carolina
- Niagra Falls, New York
- Penuelas, Puerto Rico
- University Park, Illinois
- Sell to IPP
- News
- Media
- Contact Us
|
|
 |
|
Need Help? or Have something for sale? USE THIS FORM:
|
|
|
|
|
|
|
|
Chillers
|
 |
|
|
|
207432
125 Ton , Zero Degree Glycol chiller, Manufactured by FES, model # 19ME. Serial # 94623042. Chiller use's 1250 lbs. of R-22 refrigerent. Skid mounted with FES digital micro control panel. Compressor is by FES and exchangers are by FES, and Thermo Power-York. National Board # 9177, MAWP is 300 psi at 400 degrees F, MDMT is -20 at 300 degrees F. Compresssor driven by a 300 hp, 4160 volt, 3575 rpm motor.Glycol Flow= 500 GPM, colling water flow= 500 gpm, Inlet temp.= 10-15 degrees F. Outlet temp. is delta 10 Degrees F.
Read More...
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Stock Number | 89094 |
| PG | SYSTEMS |
| SG | |
| SSG | |
| Capacity | |
| Product Description | 960 cfm Detrex activated carbon bed for removal of trichloroethylene vapors from air stream. Mdl SVRM-3-3.5-960, blt 1992. Skid mtd system in (3) sections. Main section has (3) 3' dia x 8' high approx 304SS activated carbon module vessels. They are insulated w/approx 2" thick insulation and covered w/sheet metal wrap. Includes connecting ductwork and piping w/valves. Sen Dure condenser, SN 270087, 5" dia x 24" long of copper construction w/2-2" openings on shell side and tube side. Condenses water and solvent during the stripping/carbon regeneration cycle. There is 10" dia x 38" high 316SS water separator to remove water from the recovered solvent. Also included on this skid is 38" wide x 12" dia x 48" high control panel. Control panel contains an Allen Bradley programmable controller and graphic display depicting system schematics w/indicator lamps designating system operation parameters and alarm conditions. This skid 192" long x 65" wide x 148" high. 2nd skid is 64" long x 52" wide x 60" high and contains an air handling blower rated 960 cfm, driven by 3 HP motor and belt drive; cool-down 550 cfm fan driven by 2 HP motor and V-belts; 15" dia x 24" high 316SS solvent recovery tank w/Dunham and Bush bronze 2x1-1/4" pump, driven by direct connected 3/60/208-230/460 volt, 3450 rpm motor. 3rd skid is 52" wide x 86" long x 55" high. This is a waste water treatment system consisting of a compartmented tank w/(3) Bell and Gossett SLC-30 circulators powered by 1/60/115 volts. Also included w/unit are (2) steam condensate recovery tanks w/pumps: (1) 15" x 15" x 10" high cast iron tank w/pump powered by 1/3 HP, 1/60/115/230 volt, 3450 rpm motor; (1) 15" x 9" x 10" high cast iron tank w/pump powered by 1/3 HP, 1/60/115/230 volt, 3450 rpm motor. Activated carbon not included. |
|
|
|
|
|
IPP Sales Contacts
|
 |
|
Keith West Global Sales KeithW@ippe.com +1 609 838 5931 | Amanda Vagell Global Sales AmandaV@ippe.com +1 609 838 5929 | Patti Buchman Global Sales PattiB@ippe.com +1 609 838 5928 | Ray Wagner Global Sales RayW@ippe.com +1 609 838 6043 | Regina Zarmer Europe Sales & Acquisitions ReginaZ@ippe.com +49-306-594-2445 Office +49-172-313-8439 Mobile +49-30-6594-2448 Fax | Jo Petrie, Sales Engineer UK, Scandinavia, Spain, & So.Africa jop@ippe.com +44 (0)1642 367 910 Office +44 (0)1642 367 913 Direct +44 (0)7770 748884 Mobile +44 (0)1642 367 920 Fax | Bohumil Cuta, E. Europe Sales & Acquisitions BohumilC@ippe.com +42-054-821-6680 Office +42-060-273-7517 Mobile +420-5-481-22240 Fax | Elisa Lucumi Central & So. America Sales ElisaL@ippe.com +1 609 838 5927
|
|
|
|
|
|
|
|
|
|
Home | About Us | Equipment Search | Plant Search | Industrial Real Estate | Sell to IPP | News | Media | Contact Us
|
Copyright 2002-2010 International Process Plants
Terms Of Use
Privacy Statement

|
|
 |