Buss Loop Reactor System |
||
|
Brief Overview |
||
|
Capacity: |
2.9 m3 working 120 deg C |
|
|
Technology: |
Buss |
|
|
Built: |
1989 |
|
|
Shut Down: |
1989 (operated only 3 months) |
|
|
Products Produced: |
- Reduction of derivatives of nitrobenzene, chlorinated nitrobenzene |
|
|
Documentation: |
Available |
|
|
Major Equipment: |
Buss Loop reactor |
|
Process Description The intensive mixing provides optimal reaction contact. Any undissolved, dispersed gas is disengaged in the autoclave and returns to the head space. As the reaction gas is consumed, fresh gas is introduced to maintain a constant reaction pressure. The temperature of the reaction mixture is controlled by the reaction heat exchanger. Catalyst is added in a suspension of raw material or solvent. The centrifugal pump used to circulate the reaction mixture is specifically designed to handle suspended catalysts. It has a special seal system that is protected by a pressurized flushing system. This system provides for: |
||
![]() ![]() ![]() ![]() ![]() ![]()
|
||